Evaluation of Corneal Biomechanical Properties following Scleral Buckling Using the Ocular Response Analyzer

نویسندگان

  • Mohammad Riazi Esfahani
  • Ebrahim Jafarzadehpur
چکیده

Purpose: To evaluate corneal visco-elasticity and intraocular pressure (IOP) changes measured by an Ocular Response Analyzer (ORA) after scleral buckling Methods: Fifty-six eyes with history of scleral buckling surgery three months ago were included in the study. Corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated IOP (IOPcc) and Goldmann-correlated IOP (IOPg) were measured by ORA 3 month postoperatively. In each group, unoperated (normal) eye was the control eye and operated eye was the case eye. Results: Twenty-seven eyes underwent buckling with encircling elements (group 1) and 29 eyes with segmental sponge (group 2). The mean (±SD) CRF in group 1 was 8.74±2.05 in operated eyes and 9.19±1.96 in control contralateral eyes, with no significant difference between them (p=0.412). In group 2 the mean (±SD) CRF was 8.14±1.95 in contralateral eyes and 9.38±2.1 in control eyes and the difference was statistically significant (p=0.024). In group 1 there was no significant difference between mean CH of cases and controls (p=0.286), but statistically significant difference between mean CH of cases and controls in group 2 (p=0.044). There were no significant differences between IOPg and IOPcc of cases and controls in two groups. Conclusion: Mean CRF and CH measurements were significantly lower after scleral buckling with segmental sponge, but no significant change in encircling procedure was observed. Also no significant change in IOPg and IOPcc in any kind of scleral buckling technique occurred postoperatively. It seems that hysteresis and CRF may measure different biomechanical aspects of ocular rigidity and are likely to be useful additional measurements in the assessment of ocular rigidity when measuring IOP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Effects of encircling scleral buckling on the morphology and biomechanical properties of the cornea].

OBJECTIVE To investigate the effects of encircling scleral buckle (SB) on corneal biomechanical properties of the cornea and its morphological parameters. METHODS We prospectively examined twelve eyes diagnosed with vitreous haemorrhage undergoing pars plana vitrectomy (PPV), and fifteen eyes undergoing combined PPV and scleral buckle (PPV/SB) for repair of rhegmatogenous retinal detachment (...

متن کامل

Ocular Response Analyzer

Until recently, corneal biomechanical properties could not be measured in vivo. The ocular response analyzer is a new, noninvasive device that analyses corneal biomechanical properties simply and rapidly. The ORA allows cornea compensated IOP measurements and can estimate corneal hysteresis (CH) and corneal resistance factor (CRF). It is designed to improve the accuracy of IOP measurement by us...

متن کامل

Evaluation of the influence of corneal biomechanical properties on intraocular pressure measurements using the ocular response analyzer.

PURPOSE The Ocular Response Analyzer (ORA) proposes to measure corneal biomechanical properties in vivo by monitoring and analyzing the corneal behavior when this structure is submitted to a force induced by an air jet. The purpose of this study was to evaluate the relationship between corneal biomechanical properties and corneal-compensated intraocular pressure (IOPCC) measurements as obtained...

متن کامل

ویژگی‌های بیومکانیکی قرنیه در بیماران مبتلا به کراتوکونوس و ارتباط آن با شدت بیماری

Background and Objective: Keratoconus is a disorder in cornea characterized by constant thinning and prominence that can result in vision defect. Due to ultrasonic changes in the corneal structure caused by keratoconus disease, its rigidity and biomechanical properties are subject to some changes. In this regard, the present study was conducted to determine the correlation of biomechanical feat...

متن کامل

Effect of Ocular Biomechanics on Intraocular Pressure Measurement in Mucopolysaccharidosis I-S (Scheie’s Syndrome)

Purpose: To study the effect of biomechanical properties of the cornea on the intraocular pressure in eyes affected with Mucopolysaccharidosis type I-S (Scheie's syndrome). Methods: Four eyes of two patients in their mid-fifties diagnosed with Scheie's syndrome were investigated for corneal biomechanical properties. The corneal biomechanical profile was assessed by the use of Ocular response an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013