A computerized method of visual acuity testing: adaptation of the early treatment of diabetic retinopathy study testing protocol.
نویسندگان
چکیده
PURPOSE To develop a computerized method of visual acuity testing for clinical research as an alternative to the standard Early Treatment for Diabetic Retinopathy Study (ETDRS) testing protocol, and to evaluate its test-retest reliability and concordance with standard ETDRS testing. DESIGN Test-retest reliability study. METHODS Multicenter setting of a study population of 265 patients at three clinical sites. Visual acuity was measured with both the electronic visual acuity testing algorithm (E-ETDRS) and standard ETDRS protocol (S-ETDRS) twice on one eye of each patient. E-ETDRS testing was conducted using the electronic visual acuity tester (EVA), which utilizes a programmed Palm (Palm, Inc, Santa Clara, California, USA) hand-held device communicating with a personal computer and 17-inch monitor at a test distance of 3 meters. RESULTS For the E-ETDRS protocol, test-retest reliability was high (r = 0.99; with 89% and 98% of retests within 0.1 logMAR and 0.2 logMAR of initial tests, respectively) and comparable with that of S-ETDRS testing (r = 0.99; with 87% and 98% of retests within 0.1 logMAR and 0.2 logMAR of initial test, respectively). The E-ETDRS and S-ETDRS scores were highly correlated (r = 0.96 for initial tests and r = 0.97 for repeat tests). Based on estimates of 95% confidence intervals, a change in visual acuity of 0.2 logMAR (10 letters) from a baseline level is unlikely to be related to measurement variability using either the E-ETDRS or the S-ETDRS visual acuity testing protocol. CONCLUSIONS The E-ETDRS protocol has high test-retest reliability and good concordance with S-ETDRS testing. The computerized method has advantages over the S-ETDRS testing in electronically capturing the data for each tested letter, requiring only a single distance for testing from 20/12 to 20/800, potentially reducing testing time, and potentially decreasing technician-related bias.
منابع مشابه
Computerized method of visual acuity testing: adaptation of the amblyopia treatment study visual acuity testing protocol.
PURPOSE To report a computerized method for determining visual acuity in children using the Amblyopia Treatment Study visual acuity testing protocol. METHODS A computerized visual acuity tester was developed that uses a programmed handheld device that uses the Palm operating system (Palm, Inc, Santa Clara, California). The handheld device communicates with a personal computer running a Linux ...
متن کاملVision change after sheet transplant of fetal retina with retinal pigment epithelium to a patient with retinitis pigmentosa.
OBJECTIVE To report the subjective and objective improvement in vision in a patient with autosomal dominant retinitis pigmentosa after transplantation of a sheet of fetal neural retina together with its retinal pigment epithelium. DESIGN A sheet of fetal neural retina with its retinal pigment epithelium was transplanted into the subretinal space under the fovea unilaterally in a patient with ...
متن کاملEffect of doxycycline vs placebo on retinal function and diabetic retinopathy progression in mild to moderate nonproliferative diabetic retinopathy: a randomized proof-of-concept clinical trial.
IMPORTANCE Microglia have been associated with inflammatory changes underlying diabetic retinopathy. OBJECTIVE To investigate whether low-dose oral doxycycline monohydrate, a drug capable of inhibiting microglial activation, can improve or slow the deterioration of retinal function and whether it can induce regression or slow progression of diabetic retinopathy in patients with mild to modera...
متن کاملعوامل موثر بر رتینوپاتی در بیماران دیابتی نوع 2 با روش تحلیل دادههای وضعیت جاری
Background: Diabetes is a chronic non-communicable disease with increasing prevalence. Retinopathy is one of the main complications of diabetes. Early diagnosis and treatment of retinopathy can reduce the risk of low vision and blindness. The aim of this study was to apply regression analysis of current status data to determine risk factors of diabetic retinopathy in patients with type 2 diabet...
متن کاملمقایسهی اثر تزریق تریامسینولون استوناید در داخل زجاجیه و زیر کپسول تنون بر میزان دید بیماران مبتلا به دیابتیک رتینوپاتی
Background and Objective: Macular edema is an important cause of visual loss in diabetic patients which can lead to permanent vision loss in untreated cases. This study compares the efficacy of intravitreal injection and the sub-tenon capsule of triamcinolone on the visual acuity in patients with diabetic retinopathy. Materials and methods: In this randomized clinical trial study, 82 diabeti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of ophthalmology
دوره 135 2 شماره
صفحات -
تاریخ انتشار 2003