Maximal expiratory flows generated by rapid chest compression following end-inspiratory occlusion or expiratory clamping in young children.

نویسندگان

  • E Kerem
  • J Reisman
  • S Gaston
  • H Levison
  • A C Bryan
چکیده

Partial forced expiratory flow-volume curves obtained by the rapid chest compression technique are being widely used to assess pulmonary function in infants and young children. The aim of this study is to assess whether in this age group flow limitation is achieved with the partial forced expiratory flow-volume curve with rapid chest compression. In eight infants and young children sedated with chloral hydrate, flow-volume curves were obtained by regular rapid chest compression technique, end-inspiratory airway occlusion prior to rapid chest compression, and expiratory clamping prior to rapid chest compression. In each technique, beginning with a cuff pressure of 20 cmH2O, the cuff pressure was increased by 10 cmH2O increments until the compression pressure reached 90 cmH2O. Maximal flow-volume curves were generated by each technique. End-inspiratory occlusion prior to rapid chest compression caused higher flows over the entire phase of expiration than the regular rapid chest compression. This increase could be observed over the entire phase of expiration. Forced expiratory flow at 50% and at 75% of vital capacity (V50 and V75) with regular rapid chest compression were 207 +/- 44 ml.s-1 (mean +/- SD) and 138 +/- 59 ml.sec-1, respectively. When end-inspiratory occlusion preceded rapid chest compression, V50 and V75 increased to 283 +/- 114 and 206 +/- 61 ml.sec-1 respectively, with a mean increase in V50 of 34% and in V75 of 31%. When expiratory clamping preceded the compression, even higher expiratory flows resulted.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery

Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...

متن کامل

Acute effects of thixotropy conditioning of inspiratory muscles on end-expiratory chest wall and lung volumes in normal humans.

Thixotropy conditioning of inspiratory muscles consisting of maximal inspiratory effort performed at an inflated lung volume is followed by an increase in end-expiratory position of the rib cage in normal human subjects. When performed at a deflated lung volume, conditioning is followed by a reduction in end-expiratory position. The present study was performed to determine whether changes in en...

متن کامل

Immediate effects of thixotropy conditioning of inspiratory muscles on chest-wall volume in chronic obstructive pulmonary disease.

INTRODUCTION Thixotropy is a passive property of the skeletal muscle that depends on the muscle's immediate history of contraction and length change. Inspiratory-muscle thixotropy affects the end-expiratory position of the rib cage in normal subjects. OBJECTIVE To determine whether a reduction in end-expiratory chest-wall volume occurs after thixotropy conditioning of inspiratory muscles in p...

متن کامل

The unique contribution of manual chest compression-vibrations to airflow during physiotherapy in sedated, fully ventilated children.

OBJECTIVE This study aimed to quantify the specific effects of manual lung inflations with chest compression-vibrations, commonly used to assist airway clearance in ventilated patients. The hypothesis was that force applied during the compressions made a significant additional contribution to increases in peak expiratory flow and expiratory to inspiratory flow ratio over and above that resultin...

متن کامل

Optimal esophageal balloon volume for accurate estimation of pleural pressure at end-expiration and end-inspiration: an in vitro bench experiment

BACKGROUND Esophageal pressure, used as a surrogate for pleural pressure, is commonly measured by air-filled balloon, and the accuracy of measurement depends on the proper balloon volume. It has been found that larger filling volume is required at higher surrounding pressure. In the present study, we determined the balloon pressure-volume relationship in a bench model simulating the pleural cav...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 8 1  شماره 

صفحات  -

تاریخ انتشار 1995