-Our Monte Carlo PET simulation for a 3D PET scan is able to simulate ~5 million coincidence events per minute per minute on 300MHz Sun dual processor workstation. This is over two orders of magnitude faster than most other available Monte Carlo simulations for 3D PET and is fast enough to be employed as a scatter correction for 3D PET imaging. We have improved the accuracy of our simulation of a clinical ECAT HR+ scanner by analyzing the effect of the energy response of the detectors on simulated sinograms. We created a modified version of our simulation for 3D PET scans using I. Our initial version was five times slower than our simulation for FDG scans. We analyzed the distribution of the simulated detected coincidence events involving gamma rays and proposed an analytical method that corrected for these events. We found that this correction is subject to errors that can be exacerbated when used in conjunction with an analytical scatter correction that scales to the measured sinogram's scatter tail. To reduce error, we have developed a faster, more detailed simulation for I. We are currently investigating the possibly of a fully Monte Carlo correction for both scatter and gamma ray coincidences in the future.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Analysis of an Improved 3D PET Monte Carlo Simulation and Scatter Correction

We are developing an accelerated Monte Carlo simulation of PET that can be uscd for scatter correction of 3D PET datn. Our Monte Carlo technique accurately accounts for single, multiple, and dual Compton scatter events, attenuation through the patient bed, activity from outside the field of view, and the true energy response of the scanner. We have incorporated innovative sampling techniques th...

متن کامل

Respiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation

Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...

متن کامل

Effect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis

Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...

متن کامل

Comparison of TOF-PET and Bremsstrahlung SPECT images of Yttrium-90: A Monte Carlo Simulation Study

Objective(s): Yttrium-90 (90Y) is a beta particle nuclide used in targeted radionuclide therapy which is available to both single-photon emission computed tomography (SPECT) and time-of-flight (TOF) positron emission tomography (PET) imaging. The purpose of this study was to assess the image quality of PET and Bremsstrahlung SPECT by simulating PET and SPECT images of 90Y using Monte Carlo simu...

متن کامل

Study of the Compton scattering effect of soft tissue in PET imaging by Monte Carlo method

Introduction:In PET imaging, one or both of two annihilation photons may change the direction before reaching the detector due to Compton scattering interaction in body. .Methods:This article, a Monte Carlo simulation study, examined the effect of soft tissue on this error.In this work, the PET BiographTM 6 scanner, a simple geometry of soft tissue -including a sphere of soft tissue in center ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001