Edema worsens target coverage in high-dose-rate interstitial brachytherapy of mobile tongue cancer: a report of two cases

نویسندگان

  • Ken Yoshida
  • Hideya Yamazaki
  • Tadayuki Kotsuma
  • Hironori Akiyama
  • Tadashi Takenaka
  • Koji Masui
  • Yasuo Yoshioka
  • Yasuo Uesugi
  • Taiju Shimbo
  • Nobuhiko Yoshikawa
  • Hiroto Yoshioka
  • Takumi Arika
  • Eiichi Tanaka
  • Yoshifumi Narumi
چکیده

PURPOSE We report our study on two patients to highlight the risk of underdosage of the clinical target volume (CTV) due to edema during high-dose-rate interstitial brachytherapy (HDR-ISBT) of mobile tongue cancer. MATERIAL AND METHODS To treat the lateral side of the CTV, flexible applicator tubes were implanted on the mouth floor. Two-dimensional planning was performed using X-ray images for Case 1, and three-dimensional (3D) planning was performed using computed tomography (CT) for Case 2. Prescribed doses for both cases were 54 Gy in nine fractions. CASE REPORTS Case 1 was treated for cancer of the right lateral border of the tongue in 2005. Tongue edema occurred after implantation, and part of the lateral border of the tongue protruded between the applicator tubes. Acute mucosal reaction abated in the protruded area earlier than in the other parts of the CTV. In this case, the tumor recurred in this area 5 months after the treatment. Case 2 was treated for cancer of the left lateral border of the tongue. Because tongue edema occurred in this case also, plastic splints were inserted between the applicator tubes to push the edematous region into the irradiated area. The mucosal surface of the CTV was covered by the 70% isodose, and 100% isodose line for before and after splint insertion. Local control of the tumor was achieved 4 years after treatment. DISCUSSION AND CONCLUSIONS To ensure sufficient target coverage, 3D image-based planning using CT should be performed, followed by re-planning using repeated CT as needed. Also, the development of devices to prevent protrusion of the edematous tissue outside the target area will help to ensure the full dosing of CTV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculation of absorbed dose rate in the lungs, ribs and skin by the mammosite applicator in breast cancer brachytherapy with MCNP

Introduction: Breast cancer is the most common cancer among women. Brachytherapy is one of the ways to treat breast cancer. In brachytherapy treatments, high-dose sources are used in interstitial placement. Here, Iridium-192 is used. This source emits gamma rays with energies ranging from 136 kV to 1060 kV electron volts. The activity of the used spring is 10 Ci. The simulated ...

متن کامل

High-dose-rate interstitial brachytherapy for mobile tongue cancer: preliminary results of a dose reduction trial

PURPOSE To compare the outcome of our facility with another about the shortened schedule (60 Gy in 10 fractions to 54 Gy in 9 fractions) of high-dose-rate interstitial brachytherapy (HDR ISBT) for mobile tongue cancer. MATERIAL AND METHODS Eighteen patients were treated with HDR ISBT as a monotherapy in dose reduction schedule with some unique technique to determine the border of tumor accura...

متن کامل

High-dose-rate interstitial brachytherapy for mobile tongue cancer: influence of the non-irradiated period.

BACKGROUND It has been demonstrated that the outcome of primary radiotherapy in squamous cell carcinomas of the head and neck is strongly influenced by overall treatment time. The purpose of this study was to evaluate the results of high-dose-rate (HDR) interstitial brachytherapy (ISBT) for early mobile tongue cancer and to examine whether the non-irradiated period affected treatment results. ...

متن کامل

”Maximum dose” points in cervical and endometrial cancer medium dose rate brachytherapy

Background: Best dose distribution in target volume and control of Organ at Risk (OAR) dose are the two main goals in brachytherapy. Materials and Methods: In this study in vivo dosimetry in 4 rectal points was performed by Transillumination Dosimeter (TLD) s and the measured doses were compared in different patients. One point was reported to have the maximum dose in each patient and the very ...

متن کامل

Proof of Symmetric Dose Distribution in Mammosite Applicator in Breast Brachytherapy with MCNP Simulation

Introduction: In brachytherapy treatments, high-dose sources are used in interstitial placement. In this paper, the modeling of a common breast cancer treatment applicator called MammoSite is done by the Monte Carlo simulation code. Then, to study and calculate the amount of doses in the breast and the dose rate of the organs at risk of radiation, including: lungs, ribs and ski...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2017