High Power Testing of a 17 GHz Photocathode RF Gun

نویسندگان

  • S. C. Chen
  • B. G. Danly
  • J. Gonichon
  • C. L. Lin
  • R. J. Temkin
چکیده

We report experimental high power test results on a high gradient 17 G H z RF photocathode gun. The 1 2 cell, π -mode, copper cavity was tested with 5-10 MW , 100 ns, 17.145 G H z pulses from a 24 MW Haimson Research Corp. klystron. A maximum surface electric field of 250 MeV/m was achieved corresponding to an on-axis gradient of 150 MeV/m. The gradient was verified by a preliminary electron beam energy measurement. Conditioning with ∼ 105 shots resulted in a low field emission current, less than 6 m A. Future research will concentrate on measurements of the quality of electron beams produced by ps laser photoemission.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Study of a 17 GHz High Gradient Photocathode Injector

This thesis describes experimental research on a 17 GHz photocathode RF gun. This work represents the first operation of a photocathode electron gun at a frequency above 3 GHz. Photocathode RF guns have the potential for achieving record high values of electron beam quality. The 1 2 cell, π-mode, copper cavity was tested with 5-10 MW, 100 ns, 17 GHz pulses from a 24 MW Haimson Research Corp. kl...

متن کامل

Experimental and Theoretical Investigations of a 17 GHz RF Gun

We report on experimental and theoretical investigations of a 17 GHz RF photocathode electron gun. This is the first photocathode electron gun to operate at a frequency above 2.856 GHz. The 1.5 cell, π−mode, copper cavity was tested with 50 ns pulses from a 17.150 GHz klystron amplifier built by Haimson Research Corp. A Bragg filter was used at the RF gun to reduce the reflection of parasitic m...

متن کامل

High Power Operation of a 17 GHz Photocathode RF Gun

We report the first operation of a 17 GHz RF photocathode electron gun. This is the first photocathode electron gun to operate at a frequency above 2.856 GHz. Such electron guns have the potential for achieving record high values of electron beam quality. The 1 2 cell, π -mode, copper cavity was tested with 5-10 MW, 100 ns, 17.145 GHz pulses from a 24 MW Haimson Research Corp. klystron amplifie...

متن کامل

Clic Test Facility Developments and Results

The objectives of the CLIC Test Facility (CTF) are to study the generation of short intense electron bunches using a laser driven photocathode in an RF gun, to generate 30 GHz RF power for high gradient tests of prototype CLIC components, and to test beam position monitors. The performance of the CTF has improved dramatically in the course of the past year and highlights are presented here. The...

متن کامل

EXPERIMENTAL OPERATION OF A 17 GHz PHOTOCATHODE RF GUN

Initial operation of a 17 GHz RF photocathode electron gun has been achieved at MIT. This is the first photocathode electron gun to operate at a frequency above 2.856 GHz. Such electron guns have the potential for achieving record high values of electron beam quality. The 1.5 cell, p-mode, copper cavity was tested with 5-10 MW, 100 ns, 17.145 GHz pulses from a klystron amplifier built by Haimso...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1995