Quantitative Anatomy of C7 Vertebra in Southern Chinese for Insertion of Lateral Mass Screws and Pedicle Screws

نویسندگان

  • Michael Siu Hei Tse
  • Chi Hin Chan
  • Kam Kwong Wong
  • Wing Cheung Wong
چکیده

STUDY DESIGN Retrospective study. PURPOSE To analyze the quantitative anatomy of C7 vertebra for insertion of lateral mass screws and pedicle screws in Southern Chinese patients. OVERVIEW OF LITERATURE C7 lateral mass is smaller when compared to other subaxial cervical levels, which limits the length of lateral mass screws that can be used. Some studies have suggested pedicle screws for better fixation. But, this option is limited by the narrow pedicle width. METHODS We have obtained computed tomography (CT) cervical spine data in 0.625 mm slices from our radiology department. The patients were adults. CTs were from May to August, 2015. The lateral mass screw length was measured using Margerl's technique and pedicle width and pedicle screw trajectory were determined in three-dimensional reformated images. RESULTS CT scans of cervical spines of 94 patients were obtained and 188 lateral masses and pedicles of C7 vertebrae were measured. The mean lateral mass screw length was 13.2 mm (standard deviation [SD] 1.6 mm), mean outer pedicle width was 5.9 mm (SD 1.0 mm) and mean pedicle screw trajectory was 29.4 degrees (SD 3.6 degrees). Most (91.0%) of the pedicles had an outer diameter ≥4.5 mm. CONCLUSIONS The mean lateral mass screw length was longer when compared with other similar studies, while the mean outer pedicle width was narrower. Nearly 10% of the pedicles were unable to accommodate 3.5 mm screws. These findings favor the use of lateral mass screws to provide a safe and stable fixation for C7 vertebrae in Southern Chinese patients, while the final choice of fixation method should only be confirmed after careful preoperative planning with CT scan.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical accuracy of three-dimensional fluoroscopy (IsoC-3D)-assisted upper thoracic pedicle screw insertion.

Correct screw placement is especially difficult in the upper thoracic vertebrae. At the cervicothoracic junction (C7-T2), problems can arise because of the narrowness of the pedicle and the difficulty of using a lateral image intensifier there. Other upper thoracic vertebrae (T3-6) pose a problem for screw insertion also because of the narrower pedicle. We inserted 154 pedicle screws into 78 ve...

متن کامل

Lateral mass versus hybrid construct for cervical laminectomy and fusion.

Spine stabilization after C3-C7 laminectomy can be accomplished with many instrumentation options. A hybrid construct using lateral mass screws from C3 to C5 and pedicle screws at C7 can potentially maximize strength and solve the spatial constraints introduced by the placement of C6 lateral mass screws and C7 pedicle screws. Seven cadaveric cervical spines from C2 to T2 were potted in a custom...

متن کامل

Morphological Study of Subaxial Cervical Pedicles by Using Three-Dimensional Computed Tomography Reconstruction Image

Malpositioning of cervical screws risks neurovascular injury. A cervical screw fixation system can provide proper rigidity, alignment correction, and high rates of fusion afforded by high pullout biomechanical strength. The objective is to assess the dimensions and axis of the C3-C7 cervical pedicles. A 1-mm slice thickness computed tomography (CT) scan of the cervical spine of 30 patients (15 ...

متن کامل

Feasibility Study of Free-Hand Technique for Pedicle Screw Insertion at C7 without Fluoroscopy-Guidance

STUDY DESIGN Retrospective interventional study. PURPOSE To introduce a free-hand pedicle screw (PS) insertion technique without fluoroscopic guidance in the C7 vertebra and evaluate the procedure's feasibility and radiologic outcomes. OVERVIEW OF LITERATURE Although PS insertion at C7 has been recognized as a critical procedure in posterior cervical fusion surgery, conventional techniques ...

متن کامل

Safety and efficacy of lateral mass screws at C7 in the treatment of cervical degenerative disease

BACKGROUND To evaluate the safety and efficacy of lateral mass screws at C7 in the treatment of cervical degenerative disease. METHODS Patients with cervical degenerative disease who underwent posterior cervical fusion and fixation from 2009 to 2015 were included in the study. All complications were captured. Postoperative X-ray and computed tomography (CT) confirmed fusion at 6 and 12 months...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016