Technical feasibility of embolizing aneurysms with glue (N-butyl 2-cyanoacrylate): experimental study in rabbits.

نویسندگان

  • Dae Chul Suh
  • Kil Soo Kim
  • Soo Mee Lim
  • Hai Bin Shi
  • Choong Gon Choi
  • Ho Kyu Lee
  • Dong Man Seo
چکیده

BACKGROUND AND PURPOSE Liquid embolic agents may have potential as a therapeutic option to reconstruct a defective vessel wall. We evaluated the feasibility of transarterial glue embolization in surgically constructed carotid artery aneurysms. METHODS Reconstruction of arterial wall defects with use of glue casts was performed in 16 surgically constructed aneurysms of carotid arteries in rabbits. Via the transfemoral route, glue was injected without balloon protection through a microcatheter into the aneurysmal sac with (n = 8) and without (n = 8) a framework of coils. To identify safe and effective methods, four concentrations (28%, 33%, 40%, 50%) of glue-iodized oil mixtures were used in four aneurysms each. Immediate (n = 16) and 2-month follow-up (n = 10) postembolization angiograms were obtained to evaluate the residual aneurysmal sac and the carotid artery patency. RESULTS Continuous column injection of glue was possible in all aneurysms, without fragmented migration of the injected glue cast. Catheter sticking or breakage did not occur during catheter retrieval. Glue embolization without a framework of coils (n = 8) resulted in complete obliteration of the aneurysmal sac in five aneurysms and incomplete obliteration with a small residual lumen in three. Two aneurysms resulted in carotid occlusion after catheter removal. A follow-up angiogram (n = 4) showed decreased residual lumen in two aneurysms, no change in the complete aneurysm occlusion in one, and carotid occlusion in one. Glue embolization with a coil framework (n = 8) resulted in complete obliteration of the aneurysmal sac in six aneurysms and incomplete obliteration with a small residual lumen in two. A small amount of spillage occurred in one owing to the improper position of the microcatheter caused by a difficult neck angle to the parent artery. Follow-up angiograms (n = 6) showed decreased residual lumen in one of two aneurysms and no change of the complete occlusion in five of six aneurysms. CONCLUSION Effective glue embolization into the aneurysmal sac is technically feasible. Microcatheter position within the aneurysm, concentration of glue, and direction of the aneurysmal neck angle all must be considered. With a coil framework, glue injection was more complete, without deformity or spillage of the glue from the aneurysm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemobilia and occult cystic artery stump bleeding after a laparoscopic cholecystectomy: endovascular treatment with N-butyl cyanoacrylate.

Hemobilia is a rare phenomenon. In this case report we present an emergent transcatheter glue embolization (in which N-butyl cyanoacrylate is used as an embolizing agent) due to arteriobilary fistula occurred following the laparoscopic cholecystectomy in a 41-year-old woman.

متن کامل

A single-surgeon randomized trial comparing sutures, N-butyl-2-cyanoacrylate and human fibrin glue for mesh fixation during primary inguinal hernia repair.

BACKGROUND We sought to determine the efficacy of sutures, human fibrin glue and N-butyl-2-cyanoacrylate for mesh fixation in patients undergoing the plug and mesh procedure for groin hernia. METHODS A total of 156 patients with 167 inguinal hernias (11 bilateral) underwent a plug and mesh procedure and were randomly assigned to received either sutures (n = 59 hernias), human fibrin glue (n =...

متن کامل

BioWeld(®) Tube and surgical glue for experimental sutureless venous microanastomosis.

BACKGROUND The medial wall of mammalian veins is generally thin and fragile compared with the thick muscle seen in arteries. This makes venous microanastomoses time consuming and challenging. This study aimed to determine the feasibility and effectiveness of using the BioWeld(®) Tube in conjunction with a surgical glue (butyl-2-cyanoacrylate) in performing sutureless venous microanastomoses. ...

متن کامل

N-butyl cyanoacrylate embolotherapy: techniques, complications, and management.

The purpose of this article is to describe acute complications associated with adhesive cyanoacrylate deposition in the peripheral circulation and their management. Despite best efforts, n-butyl cyanoacrylate glue embolization is inherently unpredictable and complications do occur. An understanding of preparation techniques that minimize adverse event rates and the technical skillset required t...

متن کامل

Comparison of the use of silk sutures and cyanoacrylate tissue glue after periodontal flaps in patients with moderate periodontitis

Comparison of the use of silk sutures and cyanoacrylate tissue glue after periodontal flaps in patients with moderate periodontitis Dr. A. Mogharehabed* - Dr. SH. Mirmohammadi** *- Assistant Professor of Periodontics Dept. - Faculty of Dentistry – Isfahan University of Medical Sciences. **- Dentist. Background and Aim: The use of silk suturing materials and cyanoacrylate tissue glue are common ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 24 8  شماره 

صفحات  -

تاریخ انتشار 2003