Comparison of Neurologic and Radiographic Outcomes with Solitaire versus Merci/Penumbra Systems for Acute Stroke Intervention

نویسندگان

  • Shannon Hann
  • Nohra Chalouhi
  • Robert Starke
  • Ashish Gandhe
  • Michael Koltz
  • Thana Theofanis
  • Pascal Jabbour
  • L. Fernando Gonzalez
  • Robert Rosenwasser
  • Stavropoula Tjoumakaris
چکیده

BACKGROUND AND PURPOSE The Solitaire Flow Restoration was approved by the FDA in 2012 for mechanical thrombolysis of proximal occlusion of intracranial arteries. To compare the Solitaire FR device and the Merci/Penumbra (previously FDA approved) systems in terms of safety, clinical outcomes, and efficacy including radiographic brain parenchymal salvage. METHODS Thirty-one consecutive patients treated with the Solitaire and 20 patients with comparable baseline characteristics treated with Merci or Penumbra systems were included in the study. Primary outcome measures included recanalization rate and modified Rankin Scale score at followup. Secondary outcomes included length of procedure, incidence of symptomatic intracranial hemorrhage, 90-day mortality, and radiographic analysis of percentage area salvage. RESULTS Compared with the Merci/Penumbra group, the Solitaire group showed a statistically significant improvement in favorable outcomes (mRS ≤ 2) (69% versus 35%, P = 0.03) and symptomatic ICH rate (0 versus 15%, P = 0.05) with a trend towards higher recanalization rates (93.5% versus 75%, P = 0.096) and shorter length of procedure (58.5 min versus 70.8 min, P = 0.08). Radiographic comparison also showed a significantly larger area of salvage in the Solitaire group (81.9% versus 71.9%, P = 0.05). CONCLUSION Our study suggests that the Solitaire system allows faster, safer, and more efficient thrombectomy than Merci or Penumbra systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differences in Effectiveness among Devices for Endovascular Thrombectomy in Patients with Acute Ischemic Stroke

In the treatment of acute ischemic stroke, the proofs of effectiveness for endovascular thrombectomy have become more robust in recent times, but some questions remain on whether the effectiveness differs across different devices (e.g. Trevo, Merci, and Solitaire). In the absence of studies that have directly compared these devices with one another, comparative information relies on the results...

متن کامل

Effectiveness of mechanical endovascular thrombectomy in a model system of cerebrovascular occlusion.

BACKGROUND AND PURPOSE A number of thrombectomy devices are currently undergoing clinical evaluation; meanwhile, various novel devices are under investigation. The aims of this study were to quantify flow restoration and the particle size distribution of the effluent pursuant to MET in an in vitro occlusion model. MATERIALS AND METHODS The model system was composed of 3 elements: an ICA/MCA r...

متن کامل

Safety and Efficacy of Mechanical Thrombectomy Using Stent Retrievers in the Endovascular Treatment of Acute Ischaemic Stroke: A Systematic Review.

BACKGROUND The treatment of choice for acute ischaemic stroke is the intravenous administration of recombinant tissue plasminogen activator within 3-4.5 h of symptom onset. However, the use of a thrombolytic would be limited by its narrow therapeutic window and contraindications. As a result, in recent years, techniques such as mechanical thrombectomy have emerged, which employ thrombus retriev...

متن کامل

Complications of endovascular treatment for acute stroke in the SWIFT trial with solitaire and Merci devices.

BACKGROUND AND PURPOSE Treatment of patients with ischemic stroke after endovascular treatment requires in-depth knowledge of complications. The goal of this study was to make endovascular treatment for acute ischemic stroke safer through an in-depth review of the major periprocedural complications observed in the Solitaire FR With Intention for Thrombectomy (SWIFT) trial. MATERIALS AND METHO...

متن کامل

Merci mechanical thrombectomy retriever for acute ischemic stroke therapy: literature review.

BACKGROUND Mechanical thrombectomy is a promising adjuvant or stand-alone therapy for acute ischemic stroke (AIS) caused by occlusion of a large vessel in patients beyond the systemic thrombolysis therapeutic window. This review focuses on the clinical and angiographic outcomes of mechanical thrombectomy with use of the Merci retriever device. METHODS Available literature published to date on...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013