Interlaboratory comparison of agar dilution and Etest methods for determining the MICs of antibiotics used in management of Neisseria meningitidis infections.

نویسندگان

  • Julio A Vázquez
  • Luisa Arreaza
  • Colin Block
  • Ingrid Ehrhard
  • Stephen J Gray
  • Sigrid Heuberger
  • Steen Hoffmann
  • Paula Kriz
  • Pierre Nicolas
  • Per Olcen
  • Anna Skoczynska
  • Lodewijk Spanjaard
  • Paola Stefanelli
  • Muhamed-Kheir Taha
  • Georgina Tzanakaki
چکیده

Previous studies have shown that there is considerable variation in the methods and media used to determine the susceptibility of Neisseria meningitidis to antimicrobial agents in different countries. In this study, national and regional reference laboratories used a standardized methodology to determine the MICs of antibiotics used in the management of meningococcal infection. Fourteen laboratories participated in the study, determining the susceptibility to penicillin G, rifampin, cefotaxime, ceftriaxone, ciprofloxacin, and ofloxacin of a collection of 17 meningococci, of which 11 strains were previously defined as having intermediate resistance to penicillin (Pen(I)) by sequencing and restriction fragment length polymorphism analysis of the penA gene. The MIC was determined by agar dilution and Etest with Mueller-Hinton agar (MH), MH supplemented with sheep blood (MH+B), and MH supplemented with heated (chocolated) blood. Several laboratories encountered problems obtaining confluent growth with unsupplemented MH. MH+B was considered to give the most congruent and reproducible results among the study laboratories. The modal MIC for MH+B for each antibiotic and method was calculated to define the MIC consensus, allowing assessment of each individual laboratory's data in relation to the others. The agreement in each antibiotic/method/medium combination was defined as the percentage of laboratories with a result within one dilution of the modal result. For the whole study, an agreement of 90.6% was observed between agar dilution and Etest methods. The agreement in each laboratory/antibiotic/method combination ranged from 98.2% to 69.7%, with six laboratories demonstrating agreement higher than 90% and 11 more than 80%. The ability of the laboratories to detect the Pen(I) isolates ranged from 18.2% to 100%. The apparent difficulty in interpreting susceptibility to rifampin, particularly with the Etest method, is very interesting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Etest as an alternative to agar dilution for antimicrobial susceptibility testing of Neisseria gonorrhoeae.

We studied whether the Etest can be used as an alternative to agar dilution to determine antimicrobial susceptibilities of ceftriaxone, cefixime, and cefpodoxime in Neisseria gonorrhoeae surveillance. One hundred fifteen clinical and laboratory isolates of N. gonorrhoeae were tested following the Clinical Laboratory Improvement Amendments (CLIA)-approved CLSI standard agar dilution method and, ...

متن کامل

Evaluation of Etest for susceptibility testing of rapidly growing mycobacteria.

MICs of amikacin, cefoxitin, ciprofloxacin, clarithromycin, doxycycline, and imipenem were determined by Etest for 100 clinical strains of rapidly growing mycobacteria and compared with MICs determined by a reference agar dilution method. Etest MICs were also determined by an alternative inoculum application (agar overlay) method and compared with MICs determined by the inoculum application met...

متن کامل

Vancomycin MICs for methicillin-resistant Staphylococcus aureus isolates differ based upon the susceptibility test method used.

Recent studies have questioned treatment of serious methicillinresistant Staphylococcus aureus (MRSA) infections with vancomycin because of treatment failures, despite vancomycin MICs in the susceptible category (MIC 2 g/ml) (2, 3, 5, 6, 7). Some of these studies have used broth microdilution for determining vancomycin MICs (5), while others have used the Etest commercial product (AB Biodisk, S...

متن کامل

Comparison of the Etest with agar dilution for antimicrobial susceptibility testing of Haemophilus ducreyi.

Two methods for determining the sensitivity of Haemophilus ducreyi to antimicrobial agents were compared; an agar dilution method and the Etest. The MICs of seven antimicrobial agents; penicillin V, ampicillin, trimethoprim, tetracycline, chloramphenicol, erythromycin and ciprofloxacin were determined for 20 strains of H. ducreyi. The MICs determined with the Etest and with the agar dilution me...

متن کامل

Comparison of the Etest and agar dilution for in vitro antimicrobial susceptibility testing of Campylobacter.

The performance of the Etest and agar dilution for in vitro antimicrobial susceptibility of Campylobacter spp. was evaluated using a quality control strain Campylobactor jejuni ATCC 33560, and 81 C. jejuni and 54 Campylobacter coli isolates recovered from retail raw meats. Seven antimicrobial agents: chloramphenicol, ciprofloxacin, doxycycline, erythromycin, gentamicin, nalidixic acid and tetra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Antimicrobial agents and chemotherapy

دوره 47 11  شماره 

صفحات  -

تاریخ انتشار 2003