Development of Multicolor Flow Cytometry Calibration Standards: Assignment of Equivalent Reference Fluorophores (ERF) Unit

نویسندگان

  • Lili Wang
  • Adolfas K. Gaigalas
چکیده

A procedure is described for assigning the number of equivalent reference fluorophores (ERF) values to microspheres labeled with a fluorophore designed to produce a fluorescence response in a given fluorescence channel of a multicolor flow cytometer. A fluorimeter was calibrated by a series of solutions of the reference fluorophores. The fluorimeter was used to obtain the microsphere fluorescence intensity, and a multicolor flow cytometer was used to obtain the microsphere concentration. The microsphere fluorescence intensity and the concentration were used to obtain the value of ERF for each model microsphere calibration standard. The procedure is described in detail only for microspheres with allophycocyanin (APC) immobilized on the surface. ERF values were also determined for microsphere calibrators for three other fluorescence channels: fluorescein isothiocyanate (FITC), phycoerythrin (PE), and Pacific Blue(PB). The four model microsphere calibrators provide a one point calibration for the four channels of a flow cytometer. By using software controls and changing the photomultiplier voltages, it is possible to obtain a multipoint calibration for each fluorescence channel using each microsphere calibrator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Toward quantitative fluorescence measurements with multicolor flow cytometry.

A procedure is presented for calibrating the output of a multicolor flow cytometer in units of antibodies bound per cell (ABC). The procedure involves two steps. First, each of the fluorescence channels of the flow cytometer is calibrated using Ultra Rainbow beads with assigned values of equivalent number of reference fluorophores (ERF). The objective of this step is to establish a linear relat...

متن کامل

Toward Quantitative Comparison of Fluorescent Protein Expression Levels via Fluorescent Beads

Establishing an e↵ective engineering discipline always requires standardized and comparable units of measurement. Such measurements serve as a means of communication between the people and machines interacting with a project, ensure compatibility between components, and allow prediction of the results of design decisions. Regulating gene expression is foundational for organism engineering, and ...

متن کامل

Measurement of Microsphere Concentration Using a Flow Cytometer with Volumetric Sample Delivery

Microsphere concentrations are needed to assign equivalent reference fluorophores (ERF) units to microspheres used in quantitative flow cytometry. A flow cytometer with a syringe based sample delivery system was evaluated for the measurement of the concentration of microspheres contained in a vial of lyophilized microspheres certified by BD Biosciences to contain 50,600 microspheres. The concen...

متن کامل

A 40-mhz Frequency Multiplexed Electronic System for Multicolor Droplet Flow Cytometry

Multiparameter flow cytometry is commonly used for the analysis of cells and droplet microreactors. However, their cost and complexity limits its applications in point-of-care systems. This paper demonstrates a high speed frequency multiplexed electronic detector for multicolor flow cytometry. The system can detect multiple fluorophores on a single PMT, rather than one per fluorophore. The dete...

متن کامل

Quantitating Fluorescence Intensity From Fluorophores: Practical Use of MESF Values

The present work uses fluorescein as the model fluorophore and points out critical steps in the use of MESF (Molecules of Equivalent Soluble Fluorophores) values for quantitative flow cytometric measurements. It has been found that emission spectrum matching between a reference solution and an analyte and normalization by the corresponding extinction coefficient are required for quantifying flu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 116  شماره 

صفحات  -

تاریخ انتشار 2011