Clinical application of remote monitoring in post-pacemaker implantation follow-up

نویسندگان

  • Rui Wang
  • He Huang
  • Yu Liu
  • Bin Kong
چکیده

This study aims to evaluate the clinical application values of Remote Monitoring (RM) in postpacemaker implantation follow-up. A total of 105 patients implanted with Dual-Chamber Pacemaker (DCPM) in our hospital were divided into the HM group (n=59, implanted the HM system, Biotronik, German) and the control group (group N, n=46). The Average Outpatient Follow-Up Times (AOFT), alarm events, all-cause mortality, stroke rate, cardiogenic readmission rate, arrhythmia, and heart functions between the two groups within 12 mon after the implantation were then compared. The followup lasted 359.21 ± 17.23 d, and 26452 pieces of data were accumulatively obtained by the HM system network center, including daily data alarm events (n=813), among which "Missing messages>7 d" accounted for 37.98%, and "mode switching" accounted for 20.83%. Compared with group N, AOFT of each patient in group RM was significantly less (P<0.01); the patients with new-onset stroke or readmitted were less (P<0.05); the patients with new-onset atrial fibrillation were more (P<0.05); the patients with NYHA III were less (P<0.05), but the mortality, patients with new-onset atrial tachycardia, ventricular tachycardia, or ventricular fibrillation, and LVEF showed no significant difference. RM could be safely and effectively applied in following up the DCPM patients, and could effectively reduce the outpatient follow-up times, detect asymptomatic arrhythmic events, effectively reduce the occurrence of cardio-cerebrovascular events through timely intervention, and improve heart functions and readmission risk.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Remote Monitoring of Cardiac Implantable Electronic Devices

Pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization devices use advanced diagnostic functions to continuously monitor the patient and the device itself. Follow-up is necessary after implantation to provide individualized treatment and to detect malfunctions. Routine office visits, however, do not provide access to these data on a timely basis. Transtelephonic pace...

متن کامل

Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study

Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...

متن کامل

Complete Congenital Heart Block in a Neonatal Lupus Erythematosus Associated with Pulmonary Involvement without Pacemaker Implantation: A Case Report

Background: Neonatal lupus erythematosus is an uncommon disease. Congenital complete heart block (CCHB) usually happens in neonates with maternal systemic lupus erythematosus. The most prevalent presentation of CCHBis bradycardiathatcanbediagnosed through an electrocardiogram. Case report: Here in, we present the case of a full-term male neonate with gestational age of 37 weeks and birth weigh...

متن کامل

Design of the Pacemaker REmote Follow-up Evaluation and Review (PREFER) trial to assess the clinical value of the remote pacemaker interrogation in the management of pacemaker patients

BACKGROUND Although pacemakers are primarily used for the treatment of bradycardia, diagnostic data available in current pacemakers allow them to be also used as sophisticated, continuous monitoring devices. Easy access to these stored data may assist clinicians in making diagnostic and therapeutic decisions sooner, thus avoiding potential long-term sequelae due to untreated clinical disorders....

متن کامل

Safety, Efficacy and Clinical Outcome of Direct Stent Implantation

Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017