Scoring System for Detecting Spurious Hemolysis in Anticoagulated Blood Specimens
نویسندگان
چکیده
BACKGROUND The identification of in vitro hemolysis (IVH) using a hematology analyzer is challenging because centrifugation of the specimens cannot be performed for cell counts. In the present study, we aimed to develop a scoring system to help identify the presence of hemolysis in anticoagulated blood specimens. METHODS Thirty-seven potassium EDTA anticoagulated blood specimens were obtained, and each specimen was divided into 3 aliquots (A, B, and C). Aliquots B and C were mechanically hemolyzed by aspirating 2 and 5 times, respectively, using a 27-gauge needle and then tested; aliquot A was analyzed immediately without any hemolysis. After the cells were counted, aliquots B and C were centrifuged and the supernatants were tested for the hemolytic index and lactate dehydrogenase levels. RESULTS The 4 hematologic parameters were selected and scored from 0 to 3 as follows:< 34.0, 34.0-36.2, 36.3-38.4, and ≥38.5 for mean cell hemoglobin concentration (MCHC, g/dL); <0.02, 0.02, 0.03, and ≥0.04 for red blood cell ghosts (10(12)/L); <0.13, 0.13-0.38, 0.39-1.30, and ≥1.31 for difference value (g/dL) of measured hemoglobin and calculated hemoglobin; and <0.26, 0.26-0.95, 0.96-3.34, and ≥3.35 for difference value (g/dL) of MCHC and cell hemoglobin concentration mean. The hemolysis score was calculated by adding all the scores from the 4 parameters. At the cutoff hemolysis score of 3, the IVH of aliquots B and C were detected as 64.9% and 91.9%, respectively. CONCLUSIONS The scoring system might provide effective screening for detecting spurious IVH.
منابع مشابه
Rate of Glucose Utilization by Blood Cells in Serum and Plasma Specimens With or Without Using Preservative
Objective: This study aims to estimate and compare the time-course change in blood glucose levels by blood cells in serum, and plasma with or without preservatives, which may reflect the rate of glucose utilization by blood cells. Method: This laboratory-based cross-sectional study was carried out using a blood specimen of 28 participants among which 14 were diagnosed with diabetes and 14 were...
متن کاملSpurious hemolysis does not influence the reliability of digoxin testing on Siemens RXL MAX and Roche Cobas e601.
Little information is available on the influence of spurious hemolysis on digoxin immunoassays. Seventeen consecutive, non-hemolyzed, sodium-heparin samples were divided in three aliquots. The first was immediately centrifuged and tested for hemolysis index (HI), as well as plasma digoxin on Siemens RXL MAX using the Siemens Dimension Flex and Roche Cobas e601 by electrochemiluminescent (ECLIA)...
متن کاملPlatelet Satellitism in a Three and Half Year Old Girl with Hemolytic Anemia and Normal Platelet Count
Platelet adherence surrounding leucocytes in a rosette formation or platelet satellitism is a rare phenomenon. This finding has been observed almost exclusively in Ethylenediaminetetraacetic acid treated blood at room temperature. The mechanism underlying this phenomenon is not fully understood. In many reports of platelet satellitism platelets clump to polymorphonuclear neutrophils in healthy...
متن کاملDoes Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?
INTRODUCTION Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. METHODS The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest(®)) for potass...
متن کاملHemolysis during component preparation: An inadvertent cause
W i n t r o d u c e d a n e w t y p e o f blood bags from two different manufacturers at our center with diversion pouch and sampling device. Stripping of tube segments was also introduced to have anticoagulated blood in satellite tube. During component preparation, we observed 11 blood bags were showing pinkish to red colored plasma immediately after first centrifugation which was suggestive o...
متن کامل