Application of Pulse Compression Signal Processing Techniques to Electromagnetic Acoustic Transducers (emats) for Non-contact Thickness Measurements and Imaging
نویسندگان
چکیده
A pair of non-contact EMATs has been used for thickness measurements and imaging of metallic plates. This was performed using wide bandwidth EMATs and pulsecompression signal processing techniques, using chirp excitation. This gives a greatly improved Signal to Noise Ratio (SNR) for non-contact experiments, increasing the speed of data acquisition. A numerical simulation of the technique has confirmed the performance. Experimental results indicate that it is possible to perform non-contact ultrasonic imaging and thickness gauging in a wide range of metal plates. Advantages over conventional transient or tone-burst excitation will be discussed. Introduction: Electromagnetic transducers have been used for the non-contact generation and detection of ultrasonic signals in metals for some time [1-3]. They consist basically of a coil and a magnetic field, applied to a conducting substrate. The transmitter coil is conventionally driven with a transient current pulse. The characteristics of an EMAT as an ultrasonic source depend on the direction of the applied magnetic field, B, and eddy current density, J, induced at a conducting surface. The presence of a Lorentz force, F, on the substrate causes an elastic wave to propagate into the volume of the material, or along the surface. EMAT detection works via an inverse process, where motion of the surface induces current into the coil. The exact wave mode to which the EMAT is sensitive depends on the coil and magnetic field configuration. There are many examples, including meander-line, pancake and rectangular coils [4-6]. Meanderline coils, shown schematically in Figure 1(a), can be used for generating Rayleigh (surface) waves, Lamb waves in thinner material and shear waves at a pre-determined angle depending upon frequency of excitation and meanderline geometry []. Spiral pancake coils can be used to generate and detect radially polarised bulk shear waves (Figure 1(b)) [], and rectangular coils are also useful for many types of acoustic modes, as shown in Figures 1(c) and (d). These EMATs have been used for many applications, such as the analysis of adhesive bonds [,], thickness measurements [,], and high temperature measurements [,]. Figure 1: Different types of EMAT configurations. (a) Menderline for Rayleigh and Lamb wave generation, (b) Pancake for radially polarised shear wave generation, (c) Rectangular for shear wave generation and (d) Rectangular for longitudinal wave generation. In practice, these measurements are difficult to make with EMAT systems because of the low signal to noise ratio (SNR) associated with their operation, which usually necessitates signal averaging on the oscilloscope []. This becomes ineffective for some real-time applications, especially in situations where rapid changes in timeof-arrival or amplitude are present. Recent work by Legendre et. al [] uses a wavelet-transform method to analyse Lamb wave signals which were generated and received using EMATs in highly noisy environments. This technique was used for weld testing []. Another signal processing technique, known as cepstral analysis has also been used [] to determine the separation of the peaks of the resonant frequencies, and to relate this to the time information of the received signals. In this paper, the above has been extended by applying pulse compression techniques to an EMAT system. This uses spiral pancake coils and swept-frequency (“chirp”) signals. Pulse compression has the ability to recover noisy signals without the use of high levels of signal averaging, and thus potentially increases the speed of measurements [16-18]. It has the advantage that it provides an extended time waveform such that high overall powers are transmitted, while still retaining wide bandwidth. It can also lead to excellent time resolution, while being able to recover small signals from well below the noise floor. Note that the technique has been used previously by various authors for air-coupled ultrasonic measurements, using either polymer-filmed capacitance devices or piezoelectric devices [19,20], but there is little reported work with EMATs. Experimental setup: Figure 2 shows a schematic diagram of an EMAT, which has been used throughout this paper. The transducer consists of a pancake coil, and a magnet. The pancake coil with 20 turns has a diameter of approximately 15mm. First experiment was performed to characterise the bandwidth of the transducer in trough transmission mode. This was achieved by capturing the received echo from a 10 mm thick aluminium plate. A Panametrics pulser/receiver was used to drive the EMAT with a -250V transient signal. The captured signal was sent to an Agilent oscilloscope and averaged over 1000 times, in order to improve the signal to noise ratio. Further experiments were performed using the pulse compression approach. These were implemented using an NCA 1000 pulser/receiver unit. The input signal to the source EMAT was a chirp signal with a centre frequency, fc and bandwidth, B of 2MHz. The chirp duration, T was set to 200μsec. When this was set, thickness evaluation using through-transmitted signals was carried out on different types of material placed in between the transducers, namely Aluminium, brass and copper plates of varying thicknesses. The measurements were then compared with a Kennedy digital calliper model 331-206. Imaging was also possible using an X-Y scanning stage, as shown in the block diagram of Figure 3. This included a digital oscilloscope and an external PC controller. The radially polarised shear waves generated by the source propagated through the sample, and the through-transmitted signal was received by the second EMAT. Output from the receiver was fed back into the pulse compression unit for data analysis. The pulse-compressed data was then recorded using a Tektronix TDS540 digital oscilloscope, before being transferred to a PC for data storage. The PC was also used to control the X-Y stages. The total area of the scan was set to 60mm x 60mm, at spatial intervals of 1mm. All scanning and data acquisition was controlled by LabView software. This software also extracted peak amplitude data of the transmitted signal from each waveform in the scan, and stored the data into a grid file format. The image was then plotted using Surfer version 7.0 software. The separation of the EMATs was approximately 8mm. For the purpose of imaging, a 6mm Aluminium plate was used. The plate had a 6.5mm diameter circular flat-bottomed hole, machined into one surface to a depth of 3mm. The plotted image using the EMAT-compression system was also compared with the image obtained using the Panametrics pulser/receiver system. Figure 2: Schematic diagram of a pancake coil EMAT in Aluminium casing Figure 3: Experimental setup for through-transmission measurements and defect imaging using two pancake-coil EMATs. Results & Discussion: Initial experiments were performed to measure the frequency response of the pancake coil EMAT. The EMAT was driven by a Panametrics pulser and the received signal from a 10mm thick aluminium plate is shown in Figure 3(a). The captured signal was averaged over 1000 times on the oscilloscope. Without averaging, it was impossible to identify the signal. Figure 3(b) shows the FFT of the signal in Figure 3(a). It indicates that the constructed EMAT has wide bandwidth response of approximately 6 MHz at 3dB from the peak. In general, this type of wide bandwidth response is a typical behaviour of a pancake coil. However, the use of large amount of averaging (up to 1000) is inefficient, especially when comes to online measurements and imagings.
منابع مشابه
A New Electromagnetic Acoustic Transducer Design for Generating and Receiving S0 Lamb Waves in Ferromagnetic Steel Plate
Electromagnetic acoustic transducers (EMATs) are non-contact, ultrasonic transducers that are usually kept within 5 mm from the sample surface to obtain a sufficient signal-to-noise ratio (SNR). One important issue associated with operation on a ferromagnetic plate is that the strong attraction force from the magnet can affect measurements and make scanning difficult. This paper investigates a ...
متن کاملThe Optimization of Lamb and Rayleigh Wave Generation Using Wideband-low-frequency Emats
This paper describes a non-contact ElectroMagnetic Acoustic Transducer (EMAT) that can be used to generate both Lamb and Rayleigh waves on metal samples. The generated waves are wideband and low frequency with a dominant frequency content centred on approximately 200kHz extending to around 500kHz. Detection of the waves is achieved using a linear coil detection EMAT. The transducers (generator ...
متن کاملEnhancement of signal amplitude of surface wave EMATs based on 3-D simulation analysis and orthogonal test method
The amplitude of an ultrasonic signal generated by electromagnetic acoustic transducers (EMATs) is typically low when compared to those generated by contacting transducers, which restricts the application of EMATs in the fields of nondestructive testing and nondestructive evaluation. The transmission process of a surface wave EMAT is studied, based on a previously established 3-D model, with th...
متن کاملElectromagnetic Acoustic Transducers for Robotic Nondestructive Inspection in Harsh Environments
Elevated temperature, gamma radiation, and geometric constraints inside dry storage casks for spent nuclear fuel represent a harsh environment for nondestructive inspection of the cask and require that the inspection be conducted with a robotic system. Electromagnetic acoustic transducers (EMATs) using non-contact ultrasonic transduction based on the Lorentz force to excite/receive ultrasonic w...
متن کاملElectromagnetic Acoustic Transducers Applied to High Temperature Plates for Potential Use in the Solar Thermal Industry
Concentrated Solar Plants (CSPs) are used in solar thermal industry for collecting and converting sunlight into electricity. Parabolic trough CSPs are the most widely used type of CSP and an absorber tube is an essential part of them. The hostile operating environment of the absorber tubes, such as high temperatures (400–550 °C), contraction/expansion, and vibrations, may lead them to suffer fr...