EMC’04/Sendai Characterization of AT railway traction power supply, measurement system and results
نویسنده
چکیده
Tests at the new ‘Havenspoorlijn’ (Harbor Railway Line) in The Netherlands asked for the measurement of all currents at eight positions of the railway. The differentiating/integrating measurement scheme with Rogowski coils and special integrators fulfilled the requirements with respect to accuracy, bandwidth, electromagnetic compatibility, life-time and environmental constraints. The sensors allowed unimpeded rail transport. A few out of many data gathered show the broad applicability of the system.
منابع مشابه
Power Quality Improvement in Traction Power Supply Networks
AC railway traction loads are usually huge single phase loads. As a result, a significant amount of Negative Sequence Current (NSC) is injected into utility grid. Moreover, harmonics and consumption ofreactive power are further power quality problems that the supply network is encountering. In this paper, acompensation strategy with the aid of Railway Power Conditioner (RPC) is proposed to over...
متن کاملMeasurements on 25 kV Traction Power Supply Systems
At the moment 25 kV traction power supply systems are being introduced in the Netherlands. Currently in the Netherlands a 1500 V DC system is used, however due to increasing energy demands this system is no longer sufficient. For the high-speed lines and heavy freight lines, which are under construction, the 2x25 kV AC system has been chosen. Introduction of this new technology leads to differe...
متن کاملConductive and Inductive Interferences of 25kV Railway Traction Power System on Train Signalling System – A Case Study
This paper presents a case study of the impacts of 25kV traction power system on railway signalling system using copper cables as communication links. Several forms of interferences including electromagnetic including and conductive have been investigated and remedial measures implemented, with satisfactory results. Key-Words : Traction Power System, electromagnetic interference, railway signal...
متن کاملA Direct Power Feeding System for AC Railway Networks Using Modular Multilevel Converter
Abstract Traditional railway power supply systems impose substantial power quality problems (PQ) on the utility network, such as unbalance, harmonics and a large amount of reactive power. This paper proposes a topology based on three-phase to single-phase modular multilevel converters (MMC) to obviate these problems. The MMC based traction substations (TSS) are connected directly to the utili...
متن کاملA Reliability Evaluation of High Speed Railway Traction Substation Based on the GO-FLOW Methodology
In order to assure the uninterrupted power supply of high speed railway, the reliability assessment of traction substation is essential at the design stage. Based on the system reliability engineering theory, a new system reliability analysis method called the GO-FLOW methodology is applied in the reliability assessment of traction substation of high speed railway. Considering failure and dynam...
متن کامل