X-ray phase contrast imaging with polychromatic sources and the concept of effective energy

نویسندگان

  • Peter R.T. Munro
  • Alessandro Olivo
چکیده

Grating based quantitative polychromatic x-ray phase imaging is currently a very active area of research. It has already been shown that, in such systems, the retrieved differential phase depends upon the spectral properties of the source, gratings, detector and sample. In this paper, we show that the retrieved sample absorption also depends upon the spectral properties of the gratings. Further, we compare the spectral dependence of both retrieved phase and absorption for the grating interferometer and coded aperture techniques. These results enable us to conclude that in both cases, quantitative phase imaging systems cannot be described by an effective energy which is independent of the sample. This has important implications for applications where an absolute measure of phase is important and in tomography.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors Affecting In-line Phase Contrast Imaging with a Laboratory Microfocus X-ray Source

An in-line method of phase contrast imaging is investigated using a polychromatic laboratorybased microfocus X-ray source. The effect of source size is considered, and by introducing water into the imaging path the influence of water on the phase contrast is determined. The results confirm that good phase contrast images can be achieved using a polychromatic laboratory-based X-ray source, and d...

متن کامل

Phase Contrast Imaging with High Resolution Cone Beam X-ray Computed Tomography

X-ray computed tomography (XCT) with cone beam geometry has become a very important method for non-destructive 3D-characterisation and evaluation of materials. Compact XCT systems can reach resolutions down to 1 μm and even below. However, the polychromatic nature of the source, limited photon flux and the consequent long measurement times as well as all kinds of measurement artifacts lead to l...

متن کامل

Comparison of Polychromatic and Monochromatic X-rays for Imaging

Monochromatic X-rays have been proposed for medical imaging, especially in the mammographic energy range. Our previous investigations have shown that the contrast of objects such as lesions or contrast media can be enhanced considerably by using monochromatic X-rays instead of the common polychromatic spectra. Admittedly, only one specific polychromatic spectrum and one monochromatic energy hav...

متن کامل

Synthesis and characterization of Gd2O2 S: Tb3+ phosphor powder for X-ray imaging detectors

Gadolinium oxysulfide phosphor doped with trivalent terbium have been synthesized using urea homogenous precipitation and followed by sulfurization at 800 °C under argon atmosphere. Structural and morphological of synthesized phosphor powder were characterized by x-ray diffraction (XRD), scanning electron microscopy (SEM) and Fourier transform infrared spectrometry (FT-IR). Hexagonal structure ...

متن کامل

Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources

X-ray radiographic absorption imaging is an invaluable tool in medical diagnostics and materials science. For biological tissue samples, polymers or fibre composites, however, the use of conventional X-ray radiography is limited due to their weak absorption. This is resolved at highly brilliant X-ray synchrotron or micro-focus sources by using phase-sensitive imaging methods to improve the cont...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013