Automatic Camera Calibration Applied to Medical Endoscopy

نویسندگان

  • João Pedro Barreto
  • Jose Roquette
  • Peter F. Sturm
  • Fernando Fonseca
چکیده

We present a calibration algorithm for cameras with lens distortion, that uses a single image of a planar chessboard pattern acquired in general position. The radial distortion is modeled using the first order division model, and the method provides a closed form estimation of the intrinsic parameters and distortion coefficient. The experimental evaluation shows that the calibration accuracy is comparable to state-ofthe-art algorithms requiring multiple input images. We believe that our approach is particularly well suited for the the calibration of medical endoscopes in computer aided surgery. Since the lens is mounted on the camera before each usage in the OR, the calibration procedure must be performed by the clinical practitioner with minimum effort. We solve this problem by proposing a fully automatic procedure that requires no human intervention other than acquiring the calibration image1. Camera calibration can hardly be avoided in the context of imagebased computer aided surgery. However, developing an effective method for geometric calibration of a medical endoscope is a very challenging task [4]. The reasons are the following: (i) the calibration must be very accurate; (ii) the endoscope optics introduces strong radial distortion that must be considered in the projection model; (iii) the calibration procedure has to be performed by a non-expert in the Operation Room (OR), which requires the method to be robust and fully automatic. Geometric camera calibration is a well studied topic, for which there are several methods and software currently available. Bouguet’s implementation of Zhang’s method for calibrating a camera from a minimum of three grid images is particularly popular [2, 5]. Unfortunately the calibration procedure does not meet the usability specifications stated above. The approach requires the acquisition of several grid images and the manual selection of corner points. This selection, although easily automatized for standard perspective images, it is very problematic in the presence of strong lens distortion. We can hardly imagine a medical doctor being eager to acquire 10 to 20 grid images during his regular clinical practice, and then struggle to manually select points over all this imagery. Wengert et 1Patent Pending (number 20091000069650) 0 2 4 6 8 10 12 290 300 310 320 330 340 350 360 370 380 390 Image # C en te r C oo rd in at es ( pi xe l) Estimation of the Center / Principal Points c x − Calib from Single Image

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ToF/RGB Sensor Fusion for 3-D Endoscopy

Acquisition of 3-D anatomical structure in minimally invasive surgery is an important step towards intra-operative guidance. In this context, the rst prototype of a Time-of-Flight/RGB endoscope was engineered for simultaneous range and color data acquisition. Intrinsic and stereo camera calibration are essential to achieve an intuitive visualization of colored surfaces. Due to the early prototy...

متن کامل

ToF/RGB Sensor Fusion for Augmented 3D Endoscopy using a Fully Automatic Calibration Scheme

3-D Endoscopy is an evolving field of research and offers great benefits for minimally invasive procedures. Besides the pure topology, color texture is an inevitable feature to provide an optimal visualization. Therefore, in this paper, we propose a sensor fusion of a Time-of-Flight (ToF) and an RGB sensor. This requires an intrinsic and extrinsic calibration of both cameras. In particular, the...

متن کامل

Development of a camera model and calibration procedure for oblique-viewing endoscopes.

Oblique-viewing endoscopes (oblique scopes) are widely used in medical practice. They are essential for certain procedures such as laparoscopy, arthroscopy and sinus endoscopy. In an oblique scope the viewing directions are changeable by rotating the scope cylinder. Although a camera calibration method is necessary to apply augmented reality technologies to oblique endoscopic procedures, no met...

متن کامل

Object Occlusion Detection Using Automatic Camera Calibration for a Wide-Area Video Surveillance System

This paper presents an object occlusion detection algorithm using object depth information that is estimated by automatic camera calibration. The object occlusion problem is a major factor to degrade the performance of object tracking and recognition. To detect an object occlusion, the proposed algorithm consists of three steps: (i) automatic camera calibration using both moving objects and a b...

متن کامل

Automatic Calibration of Stereo-cameras Using Ordinary Chess-board Patterns

Automation of camera calibration is facilitated by recording coded 2D patterns. Our toolbox for automatic camera calibration using images of simple chess-board patterns is freely available on the Internet. But it is unsuitable for stereo-cameras whose calibration implies recovering camera geometry and their true-to-scale relative orientation. In contrast to all reported methods requiring additi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009