Extinction effects in x-ray holographic imaging with internal reference
نویسندگان
چکیده
P. Korecki, D. V. Novikov, M. Tolkiehn, and G. Materlik Institute of Physics, Jagiellonian University, Reymota 4, 30-059 Krakow, Poland Hamburger Synchrotronstrahlungslabor HASYLAB am Deutschen Elektronen-Synchrotron DESY, 22603 Hamburg, Germany Diamond Light Source Limited, Rutherford Appleton Laboratory, Chilton, Didcot, Oxfordshire OX11 0QX, United Kingdom ~Received 8 November 2003; published 20 May 2004!
منابع مشابه
High-resolution X-ray lensless imaging by differential holographic encoding.
We demonstrate in the soft x-ray regime a novel technique for high-resolution lensless imaging based on differential holographic encoding. We have achieved superior resolution over x-ray Fourier transform holography while maintaining the signal-to-noise ratio and algorithmic simplicity. We obtain a resolution of 16 nm by synthesizing images in the Fourier domain from a single diffraction patter...
متن کاملSingle-shot femtosecond x-ray holography using extended references.
In the context of x-ray lensless imaging, we present a recent approach for Fourier transform holography based on the use of extended references. Major advances shown here rely on a high signal efficiency and on the direct image reconstruction of the object performed by a simple linear derivative. Moreover, the extended holographic reference is easy to manufacture and can be applied to a variety...
متن کاملDosimetry of Occupational Radiation around Panoramic X-ray Apparatus
Background: Panoramic imaging is one of the most common imaging methods in dentistry. Regarding the side-effects of ionizing radiation, it is necessary to survey different aspects and details of panoramic imaging. In this study, we compared the absorbed x-ray dose around two panoramic x-ray units: PM 2002 CC Proline (Planmeca, Helsinki, Finland) and Cranex Tome (Soredex, Helsinki, Finland).<br ...
متن کاملHolographic Fine Structure in Nuclear Resonant Absorption
The majority of x-ray, electron and neutron scattering techniques are based on measuring the scattered wave intensity in the far field. Probing the scattered wave field inside the sample, which can be effected by monitoring the absorption of particular atoms or nuclei of the sample, makes it possible to use Gabor's holographic formalism [1] to analyze the scattering pattern and to overcome the ...
متن کاملThe effect of alendronate treatment on cortical thickness of the proximal femur in postmenopausal women
Background: Bisphosphonates (BPs) are used extensively for managing the osteoporosis. There are some controversies on atypical fractures of femur that associated with increase in cortical thickness (CT) and BPs’ use. In this study, the effects of alendronate consumption were studied on femoral CT as a predictor for atypical fracture. Methods: Forty nine post-menopausal women age...
متن کامل