Nonenhanced hybridized arterial spin labeled magnetic resonance angiography of the extracranial carotid arteries using a fast low angle shot readout at 3 Tesla

نویسندگان

  • Ioannis Koktzoglou
  • Matthew T. Walker
  • Joel R. Meyer
  • Ian G. Murphy
  • Robert R. Edelman
چکیده

BACKGROUND To evaluate ungated nonenhanced hybridized arterial spin labeling (hASL) magnetic resonance angiography (MRA) of the extracranial carotid arteries using a fast low angle shot (FLASH) readout at 3 Tesla. METHODS In this retrospective, institutional review board-approved and HIPAA-compliant study, we evaluated the image quality (4-point scale) of nonenhanced hASL MRA using a FLASH readout with respect to contrast-enhanced MRA (CEMRA) in 37 patients presenting with neurologic symptoms. Two certified neuroradiologists independently evaluated 407 arterial segments (11 per patient) for image quality. The presence of vascular pathology was determined by consensus reading. Gwet's AC1 was used to assess inter-rater agreement in image quality scores, and image quality scores were correlated with age and body mass index. Objective measurements of arterial lumen area and sharpness in the carotid arteries were compared to values obtained with CEMRA. Comparisons were also made with conventional nonenhanced 2D time-of-flight (TOF) MRA. RESULTS CEMRA provided the best image quality, while nonenhanced hASL FLASH MRA provided image quality that exceeded 2D TOF at the carotid bifurcation and in the internal and external carotid arteries. All nine vascular abnormalities of the carotid and intracranial arteries detected by CEMRA were depicted with hASL MRA, with no false positives. Inter-rater agreement of image quality scores was highest for CEMRA (AC1 = 0.87), followed by hASL (AC1 = 0.61) and TOF (AC1 = 0.43) (P < 0.001, all comparisons). With respect to CEMRA, agreement in cross-sectional lumen area was significantly better with hASL than TOF in the common carotid artery (intraclass correlation (ICC) = 0.90 versus 0.66; P < 0.05) and at the carotid bifurcation (ICC = 0.87 versus 0.54; P < 0.05). Nonenhanced hASL MRA provided superior arterial sharpness with respect to CEMRA and 2D TOF (P < 0.001). CONCLUSION Although inferior to CEMRA in terms of image quality and inter-rater agreement, hASL FLASH MRA offers an alternative to 2D TOF for the nonenhanced evaluation of the extracranial carotid arteries at 3 Tesla. Compared with 2D TOF, nonenhanced hASL FLASH MRA provides improved quantification of arterial cross-sectional area, vessel sharpness, inter-rater agreement and image quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Balanced SSFP Spin-Labeled Angiography Using Sparse Data: Optimization and Application to Supraaortic Vessels

Introduction: Although contrast-enhanced magnetic resonance angiography (CE-MRA) remains the technique of choice for evaluating the blood vessels of the head and neck, it is now frequently contraindicated in patients with renal insufficiency at risk for nephrogenic systemic fibrosis. Pulsed arterial spin-labeled (ASL) angiography has long been proposed as a method for unenhanced MRA [1] that ma...

متن کامل

Carotid MR angiography using pulsed continuous arterial spin labeling

Introduction Carotid artery disease is a major cause of cerebral ischemia and infarction. It is routinely assessed using contrast-enhanced magnetic resonance angiography (MRA). Several methods for nonenhanced MRA exist, which may be particularly advantageous in patients with impaired renal function due to the risk of nephrogenic systemic fibrosis. Pulsed arterial spin-labeled (ASL) MRA has been...

متن کامل

Gadolinium-enhanced magnetic resonance angiography in brain death

Confirmatory tests for the diagnosis of brain death in addition to clinical findings may shorten observation time required in some countries and may add certainty to the diagnosis under specific circumstances. The practicability of Gadolinium-enhanced magnetic resonance angiography to confirm cerebral circulatory arrest was assessed after the diagnosis of brain death in 15 patients using a 1.5 ...

متن کامل

Nonenhanced MR angiography of the pulmonary arteries using single-shot radial quiescent-interval slice-selective (QISS): a technical feasibility study

BACKGROUND For evaluation of the pulmonary arteries in patients suspected of pulmonary embolism, CT angiography (CTA) is the first-line imaging test with contrast-enhanced MR angiography (CEMRA) a potential alternative. Disadvantages of CTA include exposure to ionizing radiation and an iodinated contrast agent, while CEMRA is sensitive to respiratory motion and requires a gadolinium-based contr...

متن کامل

Comparison of magnetic resonance volume flow rates, angiography, and carotid Dopplers. Preliminary results.

BACKGROUND AND PURPOSE We compared the results of conventional angiography, carotid Doppler, and magnetic resonance angiography volume flow rates to determine the clinical utility of volume flow rate assessment of blood flow to the anterior circulation in patients with carotid occlusive disease. METHODS From 11 symptomatic patients, a total of 22 extracranial carotid arteries were studied wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2016