An illustrated comparison of processing methods for MR phase imaging and QSM: combining array coil signals and phase unwrapping

نویسندگان

  • Simon Daniel Robinson
  • Kristian Bredies
  • Diana Khabipova
  • Barbara Dymerska
  • José P. Marques
  • Ferdinand Schweser
چکیده

Phase imaging benefits from strong susceptibility effects at very high field and the high signal-to-noise ratio (SNR) afforded by multi-channel coils. Combining the information from coils is not trivial, however, as the phase that originates in local field effects (the source of interesting contrast) is modified by the inhomogeneous sensitivity of each coil. This has historically been addressed by referencing individual coil sensitivities to that of a volume coil, but alternative approaches are required for ultra-high field systems in which no such coil is available. An additional challenge in phase imaging is that the phase that develops up to the echo time is "wrapped" into a range of 2π radians. Phase wraps need to be removed in order to reveal the underlying phase distribution of interest. Beginning with a coil combination using a homogeneous reference volume coil - the Roemer approach - which can be applied at 3 T and lower field strengths, we review alternative methods for combining single-echo and multi-echo phase images where no such reference coil is available. These are applied to high-resolution data acquired at 7 T and their effectiveness assessed via an index of agreement between phase values over channels and the contrast-to-noise ratio in combined images. The virtual receiver coil and COMPOSER approaches were both found to be computationally efficient and effective. The main features of spatial and temporal phase unwrapping methods are reviewed, placing particular emphasis on recent developments in temporal phase unwrapping and Laplacian approaches. The features and performance of these are illustrated in application to simulated and high-resolution in vivo data. Temporal unwrapping was the fastest of the methods tested and the Laplacian the most robust in images with low SNR. © 2016 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of 1-d and 2-d surface coil arrays for accelerated volume MR imaging using sensitivity encoding

The optimum phased array combined SNR (B1weighted) [5] and SENSE g-factor were computed for various coil geometries and imaging plane orientations based on simulated field maps. Magnetic fields (B1-maps) for each coil were calculated using the Biot-Savart law. The sample noise correlations between coils which are used in calculating the optimum B1-weighted combining and SENSE g-factor [1] were ...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

Windowing Effects of Short Time Fourier Transform on Wideband Array Signal Processing Using Maximum Likelihood Estimation

During the last two decades, Maximum Likelihood estimation (ML) has been used to determine Direction Of Arrival (DOA) and signals propagated by the sources, using narrowband array signals. The algorithm fails in the case of wideband signals. As an attempt by the present study to overcome the problem, the array outputs are transformed into narrowband frequency bins, using short time Fourier tran...

متن کامل

Windowing Effects of Short Time Fourier Transform on Wideband Array Signal Processing Using Maximum Likelihood Estimation

During the last two decades, Maximum Likelihood estimation (ML) has been used to determine Direction Of Arrival (DOA) and signals propagated by the sources, using narrowband array signals. The algorithm fails in the case of wideband signals. As an attempt by the present study to overcome the problem, the array outputs are transformed into narrowband frequency bins, using short time Fourier tran...

متن کامل

High Resolution Quantitative Susceptibility Mapping at 9.4T

INTRODUCTION Susceptibility weighted imaging at ultrahigh magnetic fields (B0≥7T) has become a new forefront of research, triggered by the anticipated increase in signal-to-noise ratio (SNR), higher spatial resolution, and improved contrast mechanisms. Employing these advantages superb anatomical contrast has already been demonstrated for both magnitude [1,2] and phase images [2-4]. These phase...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 30  شماره 

صفحات  -

تاریخ انتشار 2017