Cardiovascular cine imaging and flow evaluation using Fast Interrupted Steady-State (FISS) magnetic resonance
نویسندگان
چکیده
BACKGROUND Existing cine imaging techniques rely on balanced steady-state free precession (bSSFP) or spoiled gradient-echo readouts, each of which has limitations. For instance, with bSSFP, artifacts occur from rapid through-plane flow and off-resonance effects. We hypothesized that a prototype cine technique, radial fast interrupted steady-state (FISS), could overcome these limitations. The technique was compared with standard cine bSSFP for cardiac function, coronary artery conspicuity, and aortic valve morphology. Given its advantageous properties, we further hypothesized that the cine FISS technique, in combination with arterial spin labeling (ASL), could provide an alternative to phase contrast for visualizing in-plane flow patterns within the aorta and branch vessels. MAIN BODY The study was IRB-approved and subjects provided consent. Breath-hold cine FISS and bSSFP were acquired using similar imaging parameters. There was no significant difference in biplane left ventricular ejection fraction or cardiac image quality between the two techniques. Compared with cine bSSFP, cine FISS demonstrated a marked decrease in fat signal which improved conspicuity of the coronary arteries, while suppression of through-plane flow artifact on thin-slice cine FISS images improved visualization of the aortic valve. Banding artifacts in the subcutaneous tissues were reduced. In healthy subjects, dynamic flow patterns were well visualized in the aorta, coronary and renal arteries using cine FISS ASL, even when the slice was substantially thicker than the vessel diameter. CONCLUSION Cine FISS demonstrates several benefits for cardiovascular imaging compared with cine bSSFP, including better suppression of fat signal and reduced artifacts from through-plane flow and off-resonance effects. The main drawback is a slight (~ 20%) decrease in temporal resolution. In addition, preliminary results suggest that cine FISS ASL provides a potential alternative to phase contrast techniques for in-plane flow quantification, while enabling an efficient, visually-appealing, semi-projective display of blood flow patterns throughout the course of an artery and its branches.
منابع مشابه
Evaluation of left ventricular volumes and ejection fraction using fast steady-state cine MR imaging: comparison with left ventricular angiography.
Previous studies demonstrated that magnetic resonance (MR) imaging consistently underestimated angiographic measurements of left ventricular (LV) volumes. The purpose of this study was to determine whether MR imaging with steady-state free precession acquisition (SSFP) can provide improved accuracy and reproducibility in measuring cardiac function in comparison with fast spoiled gradient echo c...
متن کاملFeasibility of ultrahigh field (7 Tesla) human cardiovascular magnetic resonance imaging to assess cardiac volumes and mass validated against 1.5 T and 3T field strengths
Introduction Ultrahigh (7T) cardiovascular magnetic resonance imaging (CMR) is an emerging field of clinical research because theoretically higher signal to noise offers potential benefits for imaging coronaries, perfusion and spectroscopy. We report the first comparison of CMR at 1.5 T, 3 T and 7 T field strengths using steady state free precession (SSFP) and fast low angle shot (FLASH) cine s...
متن کاملRapid phase-modulated water excitation steady-state free precession for fat suppressed cine cardiovascular MR
BACKGROUND The purpose of this article is to describe a steady-state free precession (SSFP) sequence for fat suppressed cine cardiovascular magnetic resonance (CMR). A rapid phase-modulated binomial water excitation (WE) pulse is utilized to minimize repetition time and acquisition time. METHODS Three different water-excitation pulses were combined with cine-SSFP for evaluation. The frequency...
متن کاملHow to perform left and right ventricular function quantification in cardiac magnetic resonance imaging with a simple mouse click
Introduction Ventricular function is a primary indicator for the diagnosis and treatment monitoring of many cardiovascular diseases. Cardiac cine magnetic resonance imaging (MRI) with steady state free precession (SSFP) sequences is regarded to be the standard of reference for the assessment of ventricular function. However, manual segmentation of MRI data is a time consuming process and also s...
متن کاملMeasurement of common carotid artery lumen dynamics during the cardiac cycle using magnetic resonance TrueFISP cine imaging.
PURPOSE To demonstrate magnetic resonance (MR) measurements of vascular lumen dynamics in common carotid arteries by using true fast imaging with steady-state precession (TrueFISP) cine imaging with an aim to provide additional physiologic information on the vessels. MATERIALS AND METHODS The left and right common carotid arteries were studied in normal young men (N = 6; age = 21-24 years; bo...