Failure of a modular hip implant at the stem-sleeve interface.
نویسندگان
چکیده
In the current era of total hip arthroplasty (THA), orthopedic surgeons have several fixation options at their disposal. The modern monoblock prosthesis, introduced by Dr. Sir John Charnley, has seen many modifications since its inception in the 1970s and continues to be the most commonly used prosthesis style for primary and revision THA. Proximal modular sleeve technology was introduced in 1967 by Konstantin Sivash, modifying his original 1956 Sivash Stem design. The design is now known as the S-ROM, and although design modifications continue to date, the fundamental structure of the S-ROM remains essentially unchanged. Several other proximal modular prostheses are now currently available for use in THA. Although this similarity in design enables considerable surgical flexibility, it also links their potential for catastrophic failure. This aim of this article was to present a brief history of proximal modularity in THA and to add to the small body of literature regarding catastrophic failure in modular hip implants, including its proposed etiologies including micromotion, fretting and corrosion.
منابع مشابه
Modular hip implant fracture at the stem-sleeve interface.
The use of modular implants in femoral stem design has grown increasingly popular over the last decade because of the theoretical advantage of more flexibility and optimization of femoral anteversion, limb length, and femoral component offset. With the benefit of increased surgical flexibility, however, modularity also carries the theoretical risks of fretting at the modular surfaces, sequelae ...
متن کاملTorsional resistance and wear of a modular sleeve-stem hip system.
The torsional resistance and wear debris generation of the modular sleeve and stem S-ROM total hip system was evaluated. The results indicate that slippage of the sleeve-stem interface may occur under physiological loading conditions. Slippage is more likely to occur if the junction is contaminated by blood or tissue, or if the stem is disengaged and reimplanted into the sleeve. Significant ...
متن کاملCoupling failure between stem and femoral component in a constrained revision total knee arthroplasty.
Knee revision using constrained implants is associated with greater stresses on the implant and interface surfaces. The present report describes a case of failure of the screw coupling between the stem and the femoral component. The cause of the failure is surmised with outline of the treatment in this case with extensive femoral bone loss. Revision implant stability was augmented with the use ...
متن کاملTotal Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population
Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...
متن کاملNovel concept of a modular hip implant could contribute to less implant failure in THA: a hypothesis
Background The modularity in total hip arthroplasty (THA) allows orthopaedic surgeons for an exact reconstruction of hip biomechanical parameters especially in revision and tumor arthroplasty. Modular structured femoral stems using taper junctions showed increased implant breakage in the recent past. Presentation of the hypothesis We hypothesize that a novel modular stem-neck-interface leads ...