Evaluation of small-volume tubes for venous and capillary PT (INR) samples.

نویسندگان

  • L Onelöv
  • R Basmaji
  • A Svensson
  • M Nilsson
  • J P Antovic
چکیده

INTRODUCTION Frequent PT (INR) testing may represent a problem for patients on warfarin treatment, and capillary or small-volume tubes may be more appropriate for such patients. A demand for small-volume tubes also comes from pediatric wards. Yet, while various small-volume tubes are available, they have not been properly evaluated. METHODS Three small-volume tubes were tested (MiniCollect 3.8% citrate, MiniCollect 3.2% citrate and Microvette EDTA) and compared with a standard 4.5-mL 3.2% citrated tube. Samples were taken by venipuncture from the back of the hand and by capillary sampling from the tip of the finger. The measures were compared with those after standard venipuncture of the arm fold. A total of 180 samples, using different combinations of tubes and sampling sites, were collected from 30 volunteers. RESULTS There were no differences in the results obtained using citrate tubes for venous samples in comparison with those obtained by standard sampling, while the results when using EDTA tubes were not comparable to those obtained by standard sampling (P < 0.001), expressing systematically lower values (by about 10%). The results observed after capillary sampling were significantly different to those obtained after standard sampling. CONCLUSIONS The MiniCollect 3.2% tube may be used for PT (INR) venipuncture samples when withdrawal of a small amount of blood is preferable, while EDTA tubes should not be used for PT (INR) testing.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative study of a portable system for prothrombin monitoring using capillary blood against venous blood measurements in patients using oral anticoagulants: correlation and concordance.

BACKGROUND Oral anticoagulants (OAC) are widely used in cardiology and are mainly indicated in cases of atrial fibrillation and prosthetic heart valves. Regular prothrombin time (PT) control is required for patients using OAC. New portable monitoring systems for measuring prothrombin time, eliminate the need to collect blood by venous puncture and facilitate daily life for these patients. OBJ...

متن کامل

A comparative study of conventional versus new, magnesium-poor Vacutainer® Sodium Citrate blood collection tubes for determination of prothrombin time and INR.

INTRODUCTION Conventional Vacutainer® Sodium Citrate blood collection tubes contain a relatively high concentration of contaminating magnesium ions, which may result in shortening of the prothrombin time (PT) and the International Normalized Ratio (INR). Recently the manufacturer of Vacutainer® Sodium Citrate tubes introduced new tubes with a magnesium-poor stopper. The magnesium concentration ...

متن کامل

Use of EDTA samples for prothrombin time measurement in patients receiving oral anticoagulants.

BACKGROUND AND OBJECTIVES Oral anticoagulant therapy is commonly called for in health care. Hitherto sampling for prothrombin time (PT) has been measured on blood collected into a coagulation tube and diluted in citrate solution. Blood samples anticoagulated with EDTA are used for hematologic tests and the same sample could also be available for PT. DESIGN AND METHODS We studied 107 patients ...

متن کامل

Evaluation of Hemoglobin Concentration of Cord, Capillary and Venous sampling in Neonates

Abstract Background Anemia is one of the most common abnormalities in pediatric medicine. Considerable differences are seen in the peripheral blood indices of infants in developing countries. The aim of this study was to determine and compared blood hemoglobin concentration in three sites of sampling in neonate. Materials and Methods 1600 term and preterm new infant in three sites of sampli...

متن کامل

How to evaluate the influence of blood collection systems on the international sensitivity index. Protocol applied to two new evacuated tubes and eight coagulometer/thromboplastin combinations.

Previous reports indicate that the international sensitivity index (ISI) of coagulometer/thromboplastin combinations (measuring systems) may be influenced by blood collection systems. We applied a new protocol to assess the extent with which two new blood collection systems (evaluation tubes) influence the ISI of eight widely used measuring systems. The evaluation tubes were made of plastic and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of laboratory hematology

دوره 37 5  شماره 

صفحات  -

تاریخ انتشار 2015