Comparison of stroke volume and fluid responsiveness measurements in commonly used technologies for goal-directed therapy.

نویسندگان

  • Simon J Davies
  • Simran Minhas
  • R Jonathan T Wilson
  • David Yates
  • Simon J Howell
چکیده

STUDY OBJECTIVE To compare stroke volume (SV) and preload responsiveness measurements from different technologies with the esophageal Doppler monitor (EDM). DESIGN Prospective measurement study. SETTING Operating room. PATIENTS 20 ASA physical status 3 patients undergoing vascular, major urological, and bariatric surgery. INTERVENTIONS Subjects received fluids using a standard Doppler protocol of 250 mL of colloid administered until SV no longer increased by >10%, and again when the measured SV decreased by 10%. MEASUREMENTS Simultaneous readings of SV, stroke volume variation (SVV) and pulse pressure variation (PPV) from the LiDCOrapid, and SVV from the FloTrac/Vigileo were compared with EDM measurements. The pleth variability index (PVI) also was recorded. MAIN RESULTS No correlation was seen in percentage SV change as measured by either the LiDCOrapid (r=0.05, P=0.616) or FloTrac (r=0.09, P= 0.363) systems compared with the EDM. Correlation was present between the LiDCOrapid and FloTrac (r=0.515, P<0.0001). Percentage error compared with the EDM was 81% for the FloTrac and 90% for the LiDCOrapid. SVV as measured by LiDCOrapid differed for fluid responders and nonresponders (10% vs 7%; P=0.021). Receiver operator curve analysis to predict a 10% increase in SV from the measured variables showed an area under the curve of 0.57 (95% CI 0.43-0.72) for SVV(FloTrac), 0.64 (95% CI 0.52-0.78) for SVV(LiDCO), 0.61 (95% CI 0.46 -0.76) for PPV, and 0.59 (95% CI 0.46 -0.71) for PVI. CONCLUSIONS Stroke volume as measured by the FloTrac and LiDCOrapid systems does not correlate with the esphageal Doppler, has poor concordance, and a clinically unacceptable percentage error. The predictive value of the fluid responsiveness parameters is low, with only SVV measured by the LiDCOrapid having clinical utility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bench-to-bedside review: Functional hemodynamics during surgery - should it be used for all high-risk cases?

The administration of a fluid bolus is done frequently in the perioperative period to increase the cardiac output. Yet fluid loading fails to increase the cardiac output in more than 50% of critically ill and surgical patients. The assessment of fluid responsiveness (the slope of the left ventricular function curve) prior to fluid administration may thus not only help in detecting patients in n...

متن کامل

Incorporating Dynamic Assessment of Fluid Responsiveness Into Goal-Directed Therapy: A Systematic Review and Meta-Analysis

OBJECTIVE Dynamic tests of fluid responsiveness have been developed and investigated in clinical trials of goal-directed therapy. The impact of this approach on clinically relevant outcomes is unknown. We performed a systematic review and meta-analysis to evaluate whether fluid therapy guided by dynamic assessment of fluid responsiveness compared with standard care improves clinically relevant ...

متن کامل

Comparison of Goal-Directed Hemodynamic Optimization Using Pulmonary Artery Catheter and Transpulmonary Thermodilution in Combined Valve Repair: A Randomized Clinical Trial

Our aim was to compare the effects of goal-directed therapy guided either by pulmonary artery catheter (PAC) or by transpulmonary thermodilution (TTD) combined with monitoring of oxygen transport on perioperative hemodynamics and outcome after complex elective valve surgery. Measurements and Main Results. Forty patients were randomized into two equal groups: a PAC group and a TTD group. In the ...

متن کامل

Financial Disclosures

Needs Statement Volume expansion is recognized as critically important in optimizing patient status during surgery or in intensive care settings, and the ability to predict fluid responsiveness represents a major clinical challenge. Goal-directed perioperative fluid management using dynamic indicators of fluid responsiveness such as stroke volume has been shown to decrease postoperative morbidi...

متن کامل

Goal-directed fluid optimization based on stroke volume variation and cardiac index during one-lung ventilation in patients undergoing thoracoscopy lobectomy operations: a pilot study

OBJECTIVES This pilot study was designed to utilize stroke volume variation and cardiac index to ensure fluid optimization during one-lung ventilation in patients undergoing thoracoscopic lobectomies. METHODS Eighty patients undergoing thoracoscopic lobectomy were randomized into either a goal-directed therapy group or a control group. In the goal-directed therapy group, the stroke volume var...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical anesthesia

دوره 25 6  شماره 

صفحات  -

تاریخ انتشار 2013