Geometrical Characterisation of a 2D Laser System and Calibration of a Cross-Grid Encoder by Means of a Self-Calibration Methodology
نویسندگان
چکیده
This article presents a self-calibration procedure and the experimental results for the geometrical characterisation of a 2D laser system operating along a large working range (50 mm × 50 mm) with submicrometre uncertainty. Its purpose is to correct the geometric errors of the 2D laser system setup generated when positioning the two laser heads and the plane mirrors used as reflectors. The non-calibrated artefact used in this procedure is a commercial grid encoder that is also a measuring instrument. Therefore, the self-calibration procedure also allows the determination of the geometrical errors of the grid encoder, including its squareness error. The precision of the proposed algorithm is tested using virtual data. Actual measurements are subsequently registered, and the algorithm is applied. Once the laser system is characterised, the error of the grid encoder is calculated along the working range, resulting in an expanded submicrometre calibration uncertainty (k = 2) for the X and Y axes. The results of the grid encoder calibration are comparable to the errors provided by the calibration certificate for its main central axes. It is, therefore, possible to confirm the suitability of the self-calibration methodology proposed in this article.
منابع مشابه
A New Approach to Self-Localization for Mobile Robots Using Sensor Data Fusion
This paper proposes a new approach for calibration of dead reckoning process. Using the well-known UMBmark (University of Michigan Benchmark) is not sufficient for a desirable calibration of dead reckoning. Besides, existing calibration methods usually require explicit measurement of actual motion of the robot. Some recent methods use the smart encoder trailer or long range finder sensors such ...
متن کاملSelf-Calibration of a Lecia HDS7000 Scanner
SUMMARY Terrestrial laser scanners are widely used for metric applications of 3D modelling of buildings, bridges, tunnels and other structures. In common with any measurement system, the calibration of the laser scanner is of paramount importance to achieve the maximum possible accuracy. Even if a calibration certificate of the scanner is provided by the vendor, the scanner should be checked fr...
متن کاملRigorous approach to bore-sight self-calibration in airborne laser scanning
We present a rigorous method for estimating some of the calibration parameters in airborne laser scanning (ALS), namely the three bore-sight angles and the range-finder offset. The technique is based on expressing the system calibration parameters within the directgeoreferencing equation separately for each target point, and conditioning a group of points to lie on a common surface of a known f...
متن کاملDesign, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer
A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...
متن کاملThe effect of self-absorption correction using internal reference on determining heavy metals concentration by laser induced breakdown spectroscopy
The identification and concentration of heavy metals, which may be so harmful for the body, is determined by the method of calibration-free laser-induced breakdown spectroscopy using a special strategy. First, the plasma temperature is obtained using the Boltzmann plot. Then, a line with an inappreciable self-absorption is considered for each element as the reference. The modified intensities o...
متن کامل