Dual-loop Control Strategy for Grid-connected Inverter with LCL Filter
نویسندگان
چکیده
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results.
منابع مشابه
The Design of a New Double Loop Controller For Simultaneous Adjustment of Input and Output Voltages of Single-Phase Grid-Connected Inverter
Although LCL filters are used widely in the grid connected inverters to reduce high-orderharmonics, such a system increases system order and therefore sustainable design of closed-loopcontroller system will be complicated. Recently, the single-loop control strategy has beensuggested for L or LC filter based grid-connected inverters. However, the use of single-loopcontrol directly in LCL filter-...
متن کاملStability Improvement of Grid-connected Converter with LCL Filter based on Capacitor Current Active Damping by Computational Delay Reduction
Nowadays, LCL filters utilization to suppress the grid-connected inverter switching harmonics is expanding and various methods such as capacitor current active damping scheme could be investigated to damp out these harmonics. However, the computational delays including control system, and PWM switching delays have significant effect on damping system stability. In most of LCL filter parameter d...
متن کاملAn LCL-filtered Single-phase Multilevel Inverter for Grid Integration of PV Systems
Integration of the PV into the electrical grid needs power electronic interface. This power electronic interface should have some key features and should come up with grid codes. One of the important criteria is the quality and harmonic contents of the current being injected to the grid. High-order harmonics of the grid current should be very limited (lower than 0.3% of the fundamental current)...
متن کاملGrid Current Regulation of a Three-Phase Voltage Source Inverter With an LCL Input Filter
Many grid connected power electronic systems, such as STATCOMs, UPFCs, and distributed generation system interfaces, use a voltage source inverter (VSI) connected to the supply network through a filter. This filter, typically a series inductance, acts to reduce the switching harmonics entering the distribution network. An alternative filter is a LCL network, which can achieve reduced levels of ...
متن کاملPower injection of renewable energy sources using modified model predictive control
This paper presents a simple model predictive control (MPC) approach to control the power injection system (PIS) for renewable energy applications. A DC voltage source and a single-phase inverter that is connected to the grid by an LCL filter form the PIS. Grid voltage is considered a disturbance for the system. For eliminating this disturbance, a modified model is proposed. It is usual to ...
متن کامل