Residual shunt after ductus arteriosus occluder implantation complicated by late endocarditis.
نویسندگان
چکیده
We report the case of a 20-year-old woman who had percutaneous closure of a patent ductus arteriosus (PDA) with a 17-mm Rashkind occluder when she was 4 years of age. A small residual shunt was noted on color-flow Doppler echocardiography immediately after the procedure and at 6-month follow-up. Because of the lack of hemodynamic complications, no additional intervention was performed. Sixteen years later, she presented with recurrent bilateral bronchopneumonia that required antibiotic treatment. Chest radiography during the third episode showed a right bronchopneumonia (Figure 1). At that time, new treatment with amoxicillin and clavulanic acid was given for 10 days, but fever persisted despite this course of antibiotics. Results of the physical examination showed blood pressure of 110/70 mm Hg, pulse of 92 bpm, temperature of
منابع مشابه
Severe hemolysis complicating transcatheter occlusion of a patent ductus arteriosus: the importance of elimination of residual flow.
Transcatheter closure of a patent ductus arteriosus (PDA) is an established technique that may rarely be complicated by severe intravascular hemolysis due to residual shunt. Although conservative management has been reported, the usual approach is to invasively eliminate the residual shunt. We report a case where misjudgment of PDA size and subsequent attempted closure with only one coil led to...
متن کاملTranscatheter closure of large sized patent ductus arteriosus using the amplatzer duct occluder device.
OBJECTIVE To assess the results of anterograde transcatheter closure of a large sized patent ductus arteriosus using the Amplatzer Duct Occluder (ADO) device. STUDY DESIGN A case series. PLACE AND DURATION OF STUDY Department of Cardiology, Armed Forces Institute of Cardiology and National Institute of Heart Diseases, Rawalpindi, from January 2005 to December 2007. METHODOLOGY All patient...
متن کاملEndocarditis risk of the USCI PDA umbrella for transcatheter closure of patent ductus arteriosus.
BACKGROUND The USCI PDA Umbrella is a device to close patent ductus arteriosus (PDA) by a transcatheter technique. Human clinical trials have shown excellent efficacy in reducing or eliminating the PDA shunt, but concerns remain about the risk of infection with this device. The purpose of this study was to evaluate the risk of infection using an animal model. METHODS AND RESULTS Susceptibilit...
متن کاملPercutaneous closure of recanalised ductus arteriosus--a single-centre experience.
INTRODUCTION Restoration of blood flow through a previously occluded ductus arteriosus may occur in some patients. Treatment strategy in patients with such residual shunts has not yet been uniformly established. AIM To present single-centre experience and to attempt to establish a strategy of management of patients with residual ductus arteriosus shunts following percutaneous closure. METHO...
متن کاملPercutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder
OBJECTIVE Ventricular septal defects resulting from post-traumatic cardiac injury are very rare. Percutaneous closure has emerged as a method for treating this disorder. We wish to report our experience in three patients who underwent percutaneous closure of a post-traumatic ventricular septal defect with a patent ductus arteriosus occluder. METHODS We treated three patients with post-traumat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 125 6 شماره
صفحات -
تاریخ انتشار 2012