Test Slice Difference Technique for Low-Transition Test Data Compression
نویسندگان
چکیده
This paper presents a low power strategy for test data compression and a new decompression scheme for test vectors. In our method, we propose an efficient algorithm for scan chain reordering to deal with the power dissipation problem. Further, we also propose a test slice difference (TSD) technique to improve test data compression. It is an efficient method and only needs one extra scan cell. In experimental results, the scheme that we presented achieve high compression ratio. The power consumption is also better compared with other well-known compression techniques.
منابع مشابه
Selective Scan Slice Grouping Technique for Efficient Test Data Compression
This paper presents a selective scan slice grouping technique for test data compression. In conventional selective encoding methods, the existence of a conflict bit contributes to large encoding data. However, many conflict bits are efficiently removed using the scan slice grouping technique, which leads to a dramatic improvement of encoding efficiency. Experiments performed with large ITC’99 b...
متن کاملSelective scan slice repetition for simultaneous reduction of test power consumption and test data volume
In this paper, we present a selective scan slice encoding technique for power-aware test data compression. The proposed scheme dramatically reduces test data volume via scan slice repetition, and generates an adjacent-filled test pattern known as the favorable lowpower pattern mapping method. Experiments were performed on the large ITC’99 benchmark circuits, and results show the effectiveness o...
متن کاملAnalysis of Don’t Care Bit Filling Techniques for Optimization of Compression and Scan Power
Test power and test time have been the major issues for current scenario of VLSI testing. The test data compression is the well known method used to reduce the test time. The don’t care bit filling method can be used for effective test data compression as well as reduction in scan power. In this paper we describe the algorithm for don’t care assignment like MT(Minimum Transition)-fill technique...
متن کاملMicroplane Model M6f for Fiber Reinforced Concrete
The new microplane model M6f for fiber reinforced concrete features several improvements over the earlier versions: (i) An explicit volumetric-deviatoric split to no split transition formulation in tension which eliminates spurious contraction under tension that the earlier models suffered; (ii) tension-compression load cycles are now correctly simulated using the loading/unloading rules prescr...
متن کامل[Computed tomography colonography image assessment using colon phantom-effects of reconstructed slice thickness].
Computed tomography colonography (CTC) is a robust and reliable imaging test of the colon. Recent studies show good sensitivity for the identification of nonpolypoid (flat) lesions as well. The purpose of this study was to determine the accuracy and reproducibility of a volume-rendering (VR) and virtual gross pathology (VGP) technique for detecting a polypoid lesion phantom by varying slice thi...
متن کامل