Indoor Air Emissions from Office Equipment: Test Method Development and Pollution Prevention Opportunities
نویسندگان
چکیده
The report describes development and evaluation of a large chamber test method for measuring emissions from dry-process photocopiers. Application of the test method will lead to a better understanding of emissions from office equipment and to the development of lower emitting machines. Challenges and complications encountered in developing and implementing the test method include: heat generation, which can cause large increases in chamber temperature; finite paper supplies for photocopiers, which limit test duration; toner off-gassing between tests, or toner carryover if different types of toner are tested; varying power requirements that may require changes in chamber electrical supply; and remote starting of the machines, which is necessary to maintain chamber integrity. The test method was evaluated in two phases. Phase I was a single laboratory evaluation at Research Triangle Institute (RTI) using four, mid-range, dry-process photocopiers. Phase I results indicate that the test method provides acceptable performance for characterizing emissions, adequately identifies differences in emissions between machines both in compounds emitted and their emission rates, and is capable of measuring both intraand inter-machine variability in emissions. For Phase I, the compounds with the highest emission rates from the four different machines tested are: ethylbenzene (28,000 μg/hour), m,p-xylenes (29,000 μg/hour), o-xylene (17,000 μg/hour), 2-ethyl-1-hexanol (14,000 μg/ hour), and styrene (12,000 μg/hour). AlIndoor Air Emissions from Office Equipment: Test Method Development and Pollution Prevention Opportunities
منابع مشابه
Indoor air quality monitoring in urban areas using Smart Sensing Technology
Recently, indoor air quality has attracted the attention of policymakers and researchers as a critical issue like that of external air pollution. Indoor air quality is more important as people spend time longer indoors than outdoors. Indoor environments are closed compared to external environments providing less opportunity for the pollutants to dilute. The emissions contain many substances tha...
متن کاملIndoor Air Quality in Schools
indoor environment. The most important include indoor pollutants, outdoor pollutants near the building, pollution transport through the ventilation system, air cleaning or filtration, and indoor climate (temperature and relative humidity). Many building materials, the furnishings and equipment, and the occupants and their activities are sources of indoor pollution. Following is a list of some o...
متن کاملProbabilistic Modelling of PM2.5 Exposures in the Working Age Population of Helsinki Metropolitan Area Otto Hänninen PROBABILISTIC MODELLING OF PM2.5 EXPOSURES IN THE WORKING AGE POPULATION OF HELSINKI METROPOLITAN AREA
Fine particles are associated with hundreds of thousands annual deaths and significant increase in morbidity in Europe. Improvement of air quality and reduction of air pollution emissions are identified as the primary goals, but environmental policies can be targeted in different ways. It is clear, that optimal protection of public health is achieved by policy options reducing population exposu...
متن کاملThe effect of perceived indoor air quality on productivity loss
This theoretical study reports on the impact of perceived indoor air quality for productivity loss in air-conditioned office buildings. A new derivation of productivity calculation model based on pollution loads and contaminant removal effectiveness is applied and the effect of the improved ventilation efficiency on productivity is estimated. The findings show that the proportion dissatisfied i...
متن کاملUsing GIS and Kriging to Analyze the Spatial Distributions of the Health Risk of Indoor Air Pollution
Kriging is an interpolation technique that is used to estimate a variable at an unmeasured location from observed values at nearer locations. In this study, it is used to analyze the spatial distributions of the health risk of indoor air pollution. The study case is an air-conditioned office building that has 16 floors, located in Taipei, Taiwan. The Kriging method is used in drawing health ris...
متن کامل