A Clinically Applicable Scheme of MRI Trajectory Optimization for 3D Cartesian Acquisition
نویسندگان
چکیده
Target Audience: MR researchers and clinical scientists working on fast acquisition. Purpose: Random undersampling is an important component used with Parallel Imaging 2 (PI), Compressed Sensing (CS) and their combination (PI-CS) for fast acquisition. Optimized pseudo-random trajectory results in better reconstruction yet the computation complexity of optimizing undersampling trajectory prevented it from clinical application. Lately, we proposed an efficient scheme 6 for 1D random undersampling optimization using stochastic method and reference k-space data. Here we extended and improved the scheme to optimize the 2D Cartesian undersampling in 3D acquisition for PI and CS, by using Nonlinear Grappa Operator and Coherence based objective function. In-vivo experiments showed improved reconstruction using PI-CS. Methods: The basic optimization scheme is similar to 1D undersampling optimization scheme which optimizes the subset of k-space to be sampled using reference k-space from previous scans of similar positions and/or with different contrasts. The flowchart is shown at Figure 1. The main concept of the efficient scheme is: to replace computational-costly reconstruction steps in stochastic optimization iterations with efficient Pseudo-reconstruction which only uses linear combination of pre-computed Parallel Imaging Operator results, and to use an objective function to approximate RMSE based on the Pseudo-reconstruction error. To better optimize 2D trajectories, we chose to use a nonlinear GRAPPA operator (fig. 2) and a Coherence based objective function to better approximate the RMSE of PI-CS. 1. A modified Simulated Annealing was implemented with a Gene-Algorithm based heuristic to optimize 2D sampling trajectories. 2. A 3x3 Nonlinear GRAPPA Extrapolation operator was calibrated using the reference k-space to accurately extrapolate the neighbour samples. Since the kernel size is very small, nonlinear operator which maps the data to a higher dimension of virtual coils performs better than conventional GRAPPA. The extrapolation result was only computed once since they are not related to undersampling trajectories. 3. Pseudo-Reconstruction: For any arbitrary trajectory, un-acquired samples in k-space can be recovered using the pre-computed Nonlinear GRAPPA-operator results from sampled neighbour k-space data, which only needs efficient linear combination. 4. Coherence based Objective Function was used to compare two trajectories and update current optimal solution in iteration of stochastic optimization. Instead of error peak, we defined a new objective function to achieve more accurate prediction of the recovery performance using both PI and CS. In CS, incoherence of the sampling matrix D, which equals to the peak non-dc value in point spread function, is the key for the convergence of l1 regularized optimization . Here we used the modified PI-recovery based point spread function (PSF) , in which for Fourier transform. is the pseudo-sampling operation resulted from pseudo-reconstruction results, which is a combination of D, sampling operation (1 for sampled points), and E, the normalized accuracy of pseudo-reconstruction ( 1 if perfectly recovered). The objective function was modified accordingly: ‖ ‖ , ≫ . Results: Two brain T1w/T2w datasets (FFE sequence/ 230×230mm/256×256 matrix/16 slices) were acquired on a Philips 3T system (Philips Healthcare, Best, the Netherland) with an 8-channel head coil (Invivo Corporation, Gainesville, FL). The datasets were all fully sampled and retrospectively under-sampled. 2D random sampling trajectories were optimized and compared with VD Poisson Disk random trajectory. The optimization scheme took about 30 seconds on Matlab on a 2.4GHz Quad CPU 64bit system. The T1w dataset was used for trajectory training, and the optimized trajectory was applied for reconstruction of another image. Figure 3 compared the L1-SPIRiT reconstruction using optimized and un-optimized trajectories. Figure 3e showed the decreasing of objective function in iterations in the stochastic optimization. Figure 4 showed the approximation of RMSE of different trajectories regressed from the objective function with/without using Nonlinear GRAPPA. Discussion: The proposed method efficiently optimized the 2D Cartesian trajectories in 3D acquisition. To tackle the problem with high degree-of-freedom, nonlinear GRAPPA operator was used to accurately extrapolate data in k-space and pre-computation enabled fast pseudo-reconstruction given any trajectory in stochastic optimization. The modified Coherence based objective function better approximates the performance of CS after PI-based recovery to better predict RMSE of PI-CS reconstruction. Results showed the scheme was efficient and effective for 2D Cartesian trajectory optimization. This scheme can benefit fast 3D acquisition and Multi-contrast imaging . This scheme is also adaptable for non-Cartesian sampling by gridding the Nonlinear GRAPPA of non-Cartesian samples to Cartesian points in pre-computation step. Conclusion: We presented an efficient scheme for 2D Cartesian trajectory optimization in 3D acquisition which can be applied clinically. References: [1] Pruessmann et.al MRM 1999 [2] Griswold, et.al. MRM 2002 [3] Lustig et. al. MRM 2007 [4] Lustig et. al. MRM 2010 [5] Gong et.al. ISMRM 2013 [6] Gong et.al. Sedona 2013 [7] Chang, et.al. MRM 2012 [8] Donoho, et.al. IEEE TIT 2006
منابع مشابه
GPU accelerated iterative SENSE reconstruction of radial phase encoded whole-heart MRI
Isotropic whole-heart imaging has become an important protocol in simplifying cardiac MRI. The acquisition time can however be a limiting factor when acquiring large field-of-views at high spatial resolutions. To reduce acquisition times, a three-dimensional (3D) acquisition scheme combining Cartesian sampling in the readout direction with a radial sampling scheme in the phase encoding plane, w...
متن کامل3D Undersampled Golden-Radial Phase Encoding Using Iterative Reconstructions and Inherent Regularization
INTRODUCTION: The reconstruction of sensitivity–encoded non–Cartesian undersampled MRI has been facilitated by the use of iterative techniques [1]. However, the ill-conditioning of the associated inverse problem produces residual aliasing and noise amplification. A proven approach to stabilize the reconstruction and to diminish these effects is the use of explicit regularization methods [2-3], ...
متن کاملMagnetization-Prepared Shells With Integrated RadiaL and Spirals
Introduction 3D magnetization-prepared fast gradient echo MR sequences, such as MP-RAGE [1], have been widely used for 3D brain volumetric imaging due to high spatial resolution and good contrast between white matter and gray matter. However, these techniques usually require long acquisition time, which increases the probability of motion and decreases clinical throughput. There have been sever...
متن کاملToward Clinically Applicable Highly-Accelerated SENSE
Introduction In images reconstructed by SENSE [1], a high acceleration factor can result in high local image noise level which often is equivalent to reduced diagnostic quality. For this reason, in clinical applications, the acceleration factor has to be restricted to values far lower than the theoretically achievable limit. To moderate this restriction, many advanced techniques [2~4] have been...
متن کاملSpiral-based 3D MR thermometry
Background/introduction Real time MR thermometry, usually based on the protonresonance frequency shift, is a key aspect of MR-guided focused ultrasound procedures. The desire to monitor the entire sonicated volume has led the field towards the development of rapid, 3D methods; however, acquiring fully sampled 3D volumetric data to monitor heating is time consuming, and so fast methods must be d...
متن کامل