Comparison between intensity and pressure as measures of sound level in the ear canal.

نویسندگان

  • S T Neely
  • M P Gorga
چکیده

In-the-ear calibration of sound pressure level may be problematic at frequencies above 2 kHz, because the pressure can vary significantly along the length of the ear canal, due to reflection of sound waves at the eardrum. This issue has been investigated by measuring behavioral thresholds to tones in a group of human subjects (N = 61) for two different insertion depths of an insert earphone. The change in insertion depth was intended to alter the distribution of pressure in the ear canal, shifting the frequency at which spectral notches occur. The inset earphone or "probe" (Etymotic ER-10C) also contained a calibrated microphone, allowing the recording of sound pressure levels in the ear canal. Prior to the threshold measurements in each subject, the Thevenin acoustic source characteristics of the probe were determined by a special calibration procedure. This calibration allowed the expression of the sound level at threshold in terms of acoustic intensity (W/m2). The impact of changes in insertion depth was determined by measuring behavioral threshold at each depth. Because cochlear sensitivity remained constant, the level of sound entering the ear at threshold should have been the same (within measurement error) for both insertions. The difference in sound pressure level (SPL) at threshold between the two probe insertions was greatest at the notch frequency of the first insertion. At this notch frequency, the SPL at threshold increased by an average of 11.4 dB. The change in sound intensity level (SIL) at threshold was almost always less than the change in SPL. At the notch frequency, the SIL decreased, on average, by only 0.5 dB. These results suggest that SIL may be a better indicator than SPL of the sound level entering the ear, especially for frequencies in the 4-8 kHz range.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of in-situ calibration methods for quantifying input to the middle ear.

Sound pressure level in-situ measurements are sensitive to standing-wave pressure minima and have the potential to result in over-amplification with risk to residual hearing in hearing-aid fittings. Forward pressure level (FPL) quantifies the pressure traveling toward the tympanic membrane and may be a potential solution as it is insensitive to ear-canal pressure minima. Derivation of FPL is de...

متن کامل

مقایسه تراز فشار صوت دو نوع کمباین مورد استفاده در ایران و بررسی برخی از عوامل موثر بر آن

Background and aims: High levels of noise that most operators of agricultural machinery are exposed to for a long time contribute to cause chronic fatigue and irreversible hearing loss. For this reason, occupational health and safety issues related to such machinary should be considered as a key criterion in the design of agricultural machinery and as a critical factor in the acceptance and sal...

متن کامل

Comparison of Transfer Functions in the Ear Canal for Open-Fitting Hearing Aids

One possibility to reduce the background noise in openfitting hearing aids is the use of active-noise-cancellationmotivated techniques for example like in [1], exploiting an ear canal microphone, which measures the sound pressure in the ear canal. In this context, a question is whether the sound pressure transfer function from the ear canal microphone of the hearing aid to the ear drum depends ...

متن کامل

Comparison of nine methods to estimate ear-canal stimulus levels.

The reliability of nine measures of the stimulus level in the human ear canal was compared by measuring the sensitivity of behavioral hearing thresholds to changes in the depth of insertion of an otoacoustic emission probe. Four measures were the ear-canal pressure, the eardrum pressure estimated from it and the pressure measured in an ear simulator with and without compensation for insertion d...

متن کامل

Sound pressure distribution and power flow within the gerbil ear canal from 100 Hz to 80 kHz.

Sound pressure was mapped in the bony ear canal of gerbils during closed-field sound stimulation at frequencies from 0.1 to 80 kHz. A 1.27-mm-diam probe-tube microphone or a 0.17-mm-diam fiber-optic miniature microphone was positioned along approximately longitudinal trajectories within the 2.3-mm-diam ear canal. Substantial spatial variations in sound pressure, sharp minima in magnitude, and h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 104 5  شماره 

صفحات  -

تاریخ انتشار 1998