Video densitometric assessment of aortic regurgitation after transcatheter aortic valve implantation: results from the Brazilian TAVI registry.
نویسندگان
چکیده
AIMS We sought to examine the feasibility and reproducibility of a new video densitometric (VD) quantification of aortic regurgitation (AR) on aortography, and its long-term clinical impact. METHODS AND RESULTS Using dedicated video densitometry software, AR after TAVI was quantified, and inter- and intra-observer reproducibility was investigated in 182 aortograms of the Brazilian TAVI registry. The aortograms were analysed using two software algorithms: 1) the quantitative regurgitation analysis (qRA) index interrogating the entire left ventricle (LV), and 2) a new method with the left ventricle outflow tract (LVOT) as a region of interest (ROI) (LVOT-AR). LVOT-AR was feasible in 64.8% vs. 29.7% of aortograms, compared with qRA index. Using the LVOT-AR, inter-observer variability was low (mean difference±standard deviation [SD]: 0.01±0.05, p=0.53), and the two observers' measurements were highly correlated (r=0.95, p<0.001). Patients with LVOT-AR >0.17 had a significantly higher one-year all-cause mortality risk compared with patients with LVOT-AR ≤0.17 (37.1% vs. 11.2%, p=0.0008). CONCLUSIONS This study proposes an alternative methodology for AR assessment after TAVI by using the LVOT method (LVOT-AR) of VD angiography. The assessment of LVOT-AR is feasible, reproducible and potentially predictive of one-year mortality.
منابع مشابه
"Balloon withdrawal technique" to correct prosthesis malposition and treat paravalvular aortic regurgitation during TAVI.
Transcatheter aortic valve implantation (TAVI) is an emerging technology used to treat high-risk patients with severe aortic stenosis. During TAVI with the CoreValve ReValving System, a balloon is used for the reduction of paravalvular regurgitation. However, in this paper, we describe the "balloon withdrawal" technique through which the positioning of a second valve can be avoided in case of i...
متن کاملLeft ventricular remodelling and prosthetic valve function after transcatheter aortic valve implantation: A serial cardiac magnetic resonance imaging study
Background Transcatheter aortic valve implantation (TAVI) has become a common procedure for high-risk patients with severe aortic stenosis. Aortic regurgitation (AR) is commonly seen after TAVI, but little is known about how it evolves over time. Similarly, the impact of TAVI on left ventricular (LV) function, LV volumes and mass is not well defined.Paravalvular aortic regurgitation (AR) is fre...
متن کاملQuantitative analysis of paravalvular leak of transcatheter aortic valves using cardiac MR
Background There is now extensive registry and clinical trial data demonstrating an increased incidence of paravalvular leak following transcatheter aortic valve implantation (TAVI) when compared with open aortic valve replacement (AVR). Despite recent improvements in both hardware and software, echocardiographic measurement of aortic regurgitation (AR) largely remains qualitative in nature. Ca...
متن کاملInitial German experience with transapical implantation of a second-generation transcatheter heart valve for the treatment of aortic regurgitation.
OBJECTIVES This analysis reports on the initial German multicenter experience with the JenaValve (JenaValve Technology GmbH, Munich, Germany) transcatheter heart valve for the treatment of pure aortic regurgitation. BACKGROUND Experience with transcatheter aortic valve implantation (TAVI) for severe aortic regurgitation is limited due to the risk of insufficient anchoring of the valve stent w...
متن کاملA CMR study assessing aortic valve hemodynamics post-transcatheter aortic valve implantation compared to surgical aortic valve replacement
Transcatheter aortic valve implantation (TAVI) removes the valvular impedance associated with aortic stenosis but can be complicated by significant aortic regurgitation. Using cardiovascular magnetic resonance we assessed the change in trans-aortic pressure gradient and regurgitant fraction 6 months post-TAVI and compared this to a surgical aortic valve replacement (SAVR) cohort. TAVI was super...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology
دوره 11 12 شماره
صفحات -
تاریخ انتشار 2016