Methods for the Characterization and Measurement of the Gain Fluctuations of Cryogenic Amplifiers

نویسندگان

  • J. D. Gallego
  • I. Lopez
  • C. Diez
  • A. Barcia
چکیده

Since ALMA instrument will have low noise receivers with very large instantaneous bandwidth, gain stability should be carefully specified to avoid limiting the sensitivity of the total system. This memorandum reviews the methods for the characterization of gain stability in the time and frequency domain and presents examples of experimental setups used for its measurement in the case of cryogenic amplifiers of the type used in the IF of ALMA as well as its practical limitations. Special attention is paid to some important but not widely known effects, as the dependence of gain fluctuation with bias and its variation across the band of the amplifier. Finally, the compliance of one prototype 4-12 GHz InP cryogenic IF amplifier with the requirements of ALMA project is discussed. Methods for the Characterization and Measurement of the Gain Fluctuations of Cryogenic Amplifiers 1. ALMA Specification: time and frequency domain The specification of gain stability for the cryogenic IF amplifier of an ALMA receiver is derived from the total System Gain Stability allowed. With the present system breakdown, the assignment for the gain stability of the cryogenic amplifier was specified in terms of Allan Variance in the time interval from 0.1 to 1.0 seconds. (sec) 1 1 . 0 10 2 ) ( 8 2 ≤ ≤ ⋅ ≤ − τ τ σ [1] A recent proposal from System Engineering (September 2006) sets different limits. The new values would be:     ≤ < ⋅ ≤ ≤ ≤ ⋅ ≤ − − (sec) 300 100 10 2 ) ( (sec) 100 05 . 0 10 2 ) ( 9 2 8 2

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Overview and Feasibility Study of Fabrication Technology and Characterization Techniques of Erbium-Doped Fiber amplifiers in Iran

In this paper, a brief summary of different methods of fabrication of optical preform and fiber is reviewed. Several methods of incorporation of erbium ions into optical preforms are studied. Characterization of the fabricated erbium doped fibers including measurements of refractive index profile, absorption, fluorescence and gain spectra and metastable lifetime are described. It is also expres...

متن کامل

The Use of Cryogenic HEMT Amplifiers in Wide Band Radiometers

Advances in device fabrication, modelling and design techniques have made wide band, low noise cryogenic amplifiers available at frequencies up to 106 GHz. Microwave radiometry applications as used in radio astronomy capitalize on the low noise and large bandwidths of these amplifiers. Radiometers must be carefully designed so as to preclude sensitivity degradations caused by small, low frequen...

متن کامل

Impact of Input Pump Profile on the Gain Spectrum and the Saturation Behavior of One-Pump Fiber Optical Parametric Amplifiers

In this article, the impact of input pump profile on the gain spectrum as well as the saturation behavior of one-pump fiber optical parametric amplifiers (FOPAs) is investigated. Since in practical circumstances, pump sources used for FOPAs have Lorentz-Gaussian profile instead of Gaussian, a more realistic case is considered for simulating FOPAs in this article. The results of simulations for ...

متن کامل

A Proposal for a New Method of Modeling of the Quantum Dot Semiconductor Optical Amplifiers

With the advancement of nanoscale semiconductor technology,semiconductor optical amplifiers are used to amplify and process all-optical signals. Inthis paper, with the aim of calculating the gain of quantum dot semiconductor opticalamplifier (QD-SOA), two groups of rate equations and the optical signal propagatingequation are used in the active layer of the device. For t...

متن کامل

Impact of Fourth-Order Dispersion Coefficient on the Gain Spectrum and the Saturation Behavior of One-Pump Fiber Optical Parametric Amplifiers

In this paper, the gain spectrum and the saturation behavior of one-pump fiber optical parametric amplifiers (1-P FOPAs) are investigated by taking into account the fourth-order dispersion coefficient b4 in the analysis. The results show that it is necessary to consider b4 in the analysis when the wavelength difference between the signal and pump waves is large enough and/or whenever the pump w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006