A simple flowmeter for unusual gases.

نویسندگان

  • I Farquhar
  • P Eldridge
چکیده

A flowmeter is described which may be used to measure gas flow in experimental situations. It may be adapted for use with any gas or gas mixture and be used to provide flows as small as 50 ml min-1. A mercury-in-glass manometer (sphygmomanometer) is used to measure the gas pressure proximal to a flow restrictor (consisting of a hypodermic needle hub) and it is this pressure head which, for a given gas, dictates the flow produced. This device may be produced at minimal cost in any hospital, is easy to calibrate and accurate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The wide-range ejector flowmeter: calibrated gas evacuation comprising both high and low gas flows.

The wide-range ejector flowmeter is an active scavenging system applying calibrated gas removal directly to the anaesthetic circuit. The evacuation rate can be adjusted on the flowmeter under visual control using the calibration scale ranging from 200 ml X min-1 to 151 X min-1. The accuracy of the calibration was tested on three ejector flowmeters at 12 different presettings. The percentage dev...

متن کامل

Nitrous oxide concentrations in the posterior nasopharynx during administration by nasal mask.

PURPOSE Nitrous oxide (N2O) administration with nasal mask produces variable outcomes in dental patients. This study describes a novel sampling method to measure actual inspired/expired N2O concentrations ([N2O]). METHODS Fifteen adult volunteers (32.5 +/- 8.5 years) underwent placement of a nasopharyngeal probe. With a nasal mask, 100% oxygen (O2) was administered for 2 minutes. N2O was intr...

متن کامل

Sudden Appearance of Water in Flowmeter During Air/Oxygen and Sevoflurane Anaesthesia.

Endotracheal intubation was performed, and a water bubbling sound was heard from the anaesthesia device immediately after the release of gases to administer the O2-air-sevoflurane mixture. The flowmeter on the anaesthesia device was then found to be filled with water. The breakdown of the dryer in the medical air compressor system was determined as the source of the problem, since a greasy flui...

متن کامل

A High-Pressure Bi-Directional Cycloid Rotor Flowmeter

The measurement of the flow rate of various liquids and gases is critical in industrial automation. Rotary positive displacement meters (rotary PD meters) are highly accurate flowmeters that are widely employed in engineering applications, especially in custody transfer operations and hydraulic control systems. This paper presents a high pressure rotary PD meter containing a pair of internal cy...

متن کامل

Improvement of simple and regenerative gas turbine using simple and ejector-absorption refrigeration

The exhaust gases of gas turbine power plant carry a significant amount of thermal energy that is usually expelled to the atmosphere this causes a reduction in net work and efficiency of gas turbine. On the other hand, the generated power and efficiency of gas turbine plants depend largely on the temperature of the inlet air, So that they both increase as the inlet air temperature decreases. Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 64 1  شماره 

صفحات  -

تاریخ انتشار 1990