Beam Size Measurements with Noninterceptive Off-Axis Screens

نویسندگان

  • F. - J. DECKER
  • R. BROWN
  • J. T. SEEMAN
چکیده

At the end of the Stanford Linear Accelerator the trans verse distributions of small electron and positron beams (u w 1OOpm) are measured by profile screens. To avoid constant interception and emittance blow-up of the production beams, the beams are deflected with fast magnets on to off-axis screens. One in a 1000 pulses is deflected. The required and achievable resolutions are described in another paper [l]. Here we concentrate more on the magnets, the screen set-up, the readout, and signal processing of the video data. Together with the kicker magnet, two PCs, one for electrons, one for positrons, are triggered recording the next frame of the camera. Hardware and software process this information quickly producing a color-enhanced picture which is displayed in the controlroom. With the resulting visual and digital information, the wakefield tails of the beam can be compensated using orbit oscillations. Minute by minute variations and slow drifts of the beam are recognizable. . .-, -_ -

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of stereotactic beam data of 9 MV X-rays using diode detector

Background: Radiosurgery is a focal brain irradiation technique that delivers, usually in a single session, high dose of ionizing radiation. The presence of lateral electronic disequilibrium and steep dose gradients in small fields demands special attention to the selection of a suitable detector with respect to its size, composition and response. Materials and Methods : Small circular fields w...

متن کامل

Dosimetric evaluation of a treatment planning system using pencil beam convolution algorithm for enhanced dynamic wedges with symmetric and asymmetric fields

Background: The dosimetric performance of Eclipse 6.5 three dimensional treatment planning system (3DTPS) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of American Association for Physicists in Medicine Task Group 53. Materials and Methods: The calculations were performed by the 3DTPS for symmetric as well as asymmetric fields for standar...

متن کامل

Off-axis primary-dose measurements using a mini-phantom.

The characterization of the incident photon beam is usually divided into its dependence on collimator setting (head-scatter factor) and off-axis position (primary off-axis ratio). These parameters are normally measured "in air" with a build-up cap thick enough to generate full dose build-up at the depth of dose maximum. In order to prevent any influence from contaminating electrons, it has been...

متن کامل

Calculation of wedged dose distributions using an analytical method

Introduction: Wedge filters are used in radiotherapy to modify photon beam and improve dose uniformity in the target volume. Determination of wedge dose distribution is important to improve treatment planning accuracy. The utilization of treatment planning software to obtain dose distribution is not always available. In this work an analytical model has been developed to calcu...

متن کامل

Quantification the dosimetric parameters of asymmetric physical wedged-6MV photon beam

Introduction: Physical wedge as a useful tool has been utilized in radiotherapy to modify photon beam shape and intensity such that it distributes dose uniformly in tumor site and reduces hot points. Since during Linac commissioning dosimetric parameters like output factors and lateral dose profiles are measured only for symmetric open and wedged fields, so calculation the par...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1993