Indium (111In)-labelled human platelets: optimal method.
نویسندگان
چکیده
1. A detailed laboratory method is described for the labelling of human platelets with [111In]indium oxine. The 45 min method is simple, requires on 26 ml of blood and is suitable for routine clinical use. 2. After the labelling and resuspension of the platelets in plasma, aggregation responses to both adenosine diphosphate and collagen were similar to those of normal platelet-rich plasma. Less than 5% of the [111In]indium oxine was released by secretory function of platelets. 3. Labelling efficiencies of 90.1 +/- 4.29% (n = 28) were achieved in 60 s by normal concentrations of plasma-free platelet suspensions. 4. Platelet survival in vivo in healthy volunteer subjects follows a linear function with a survival time of 8.44 +/- 0.18 days.
منابع مشابه
A quantitative method to measure human platelet chemotaxis using indium-111-oxine-labeled gel-filtered platelets.
Human blood platelets have been shown to migrate directionally and specifically toward collagen in plasma in vitro. We have developed a new system to monitor this behavior using a linear 7-compartment chamber with 111In-oxine-labeled gel-filtered platelets. The compartments are separated by various Nuclepore and Millipore filter membranes. Radiolabeled platelets suspended in plasma are placed i...
متن کاملPulmonary platelet kinetics in asthma.
Platelets produce a range of bronchoconstrictor mediators. Measurements of plasma factors have implicated platelet activation in allergic asthma, and sensitised guinea pigs challenged with ovalbumin show pulmonary platelet aggregation accompanying bronchoconstriction. To investigate this further we injected autologous platelets labelled with indium 111 and red cells labelled with technetium 99m...
متن کاملImproved tumour localisation using indium-111 labelled antibodies.
Immunoglobulin G (IgG) antibodies to carcinoembryonic antigen (CEA) were labelled with radioactive indium (111In) or iodine (131I) and a comparison made of their value in locating CEA producing tumours. Eleven patients given 111In-anti-CEA had 31 tumours as judged by a combination of all techniques. Of these, 28 were detected by 111In-anti-CEA and 26 by conventional clinical techniques. Five of...
متن کاملLabelled Stealth liposomes in experimental infection: an alternative to leukocyte scintigraphy?
Indium-111 (111In) and technetium-99m (99Tcm) Stealth liposomes were compared with 111In- and 99Tcm-labelled white blood cells (WBC) in experimental infection in a rabbit model. Preformed polyethylene glycol-coated liposomes and separated WBC were radiolabelled with either 111In-oxine or 99Tcm-hexamethylpropyleneamine oxime (99TcM-HMPAO). After the intravenous administration of one of the four ...
متن کاملSpleen function and platelet kinetics.
In patients suffering from various platelet abnormalities, quantitative scanning after injection of indium-111 (111In) labelled platelets showed three different patterns of platelet destruction and distribution. In patients with a normal platelet life span but with evidence of increased splenic pooling, the spleen tended to be the main site of destruction. In patients with a moderately reduced ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical science
دوره 58 3 شماره
صفحات -
تاریخ انتشار 1980