Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects
نویسندگان
چکیده
Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood pulsation. A total of 8400 corneal deformation images were recorded. The results of intraocular pressure measurements were related to the results of heartbeat phases measured with a pulse oximeter placed on the index finger of the subject's left hand. Results. The correlation between the heartbeat phase measured with a pulse oximeter and intraocular pressure is 0.69 ± 0.26 (p < 0.05). The phase shift calculated for the maximum correlation is equal to 60 ± 40° (p < 0.05). When the moment of measuring intraocular pressure with an air-puff tonometer is not synchronized, the changes in IOP for the analysed group of subjects can vary in the range of ±2.31 mmHg (p < 0.3). Conclusions. Blood pulsation has a statistically significant effect on the results of intraocular pressure measurement. For this reason, in modern ophthalmic devices, the measurement should be synchronized with the heartbeat phases. The paper proposes an additional method for synchronizing the time of pressure measurement with the blood pulsation phase.
منابع مشابه
Evaluation of the diurnal intraocular pressure fluctuations and blood pressure under dehydration due to fasting
Introduction: This study aimed to investigate the diurnal intraocular pressure fluctuations under dehydration conditions and the relationship between the intraocular pressure fluctuations and blood pressure. Methods: The intraocular pressures (IOP), body weights, as well as systolic and diastolic blood pressures (SBP, DBP) of 36 fasting healthy volunteers were recorded at 8:00 a.m. and 5:00 p.m...
متن کاملThe Correlation between Glucose and Lipid Biomarkers Variations with biometric characteristics and Intraocular Pressure Changes during Ramadan Fasting
Introduction: The aim of present study was to assess the correlation between glucose and lipid biomarkers variations with biometric characteristics and intraocular pressure changes following Ramadan fasting. Methods: A total of 100 healthy fasting volunteers were enrolled in the study. Of them, 89 subjects completed the study with respect to inclusion and exclusion criteria. Right eye ocular ax...
متن کاملEffects of acetazolamide on choroidal blood flow.
BACKGROUND AND PURPOSE The acetazolamide provocation test is commonly used to study cerebrovascular vasomotor reactivity. On the basis of the effect of a carbonic anhydrase inhibitor in the central nervous system, we hypothesized that acetazolamide may also increase blood flow in the human choroid. METHODS In a placebo-controlled, randomized, double-blind, three-way crossover design, acetazol...
متن کاملThe effect of low dose of ketamine on intraocular pressure in patients undergoing cataract surgery
Background: Cataract surgery is one of the most common surgeries in the world, especially in elderly patients, and often performed topically with sedative agents. Ketamine is one of the most commonly used agents and the effect of different doses on intraocular pressure is in dispute. The present study investigates the effect of a low dose of ketamine on intraocular pressure in patients undergoi...
متن کاملQuantitative Analysis of Fundus-Image Sequences Reveals Phase of Spontaneous Venous Pulsations.
PURPOSE Spontaneous venous pulsation correlates negatively with elevated intracranial pressure and papilledema, and it relates to glaucoma. Yet, its etiology remains unclear. A key element to elucidate its underlying mechanism is the time at which collapse occurs with respect to the heart cycle, but previous reports are contradictory. We assessed this question in healthy subjects using quantita...