Evaluation of two 99mTc-DTPA radioaerosols with different characteristics in lung ventilation studies.

نویسندگان

  • C M Silveira
  • M L V Castiglioni
  • I C G Torres
  • R B Medeiros
  • J R Jardim
چکیده

Two radioaerosol preparations, TechneScan -DTPA (99mTc-DTPA, 40 mCi/3 ml; IPEN-CNEN, São Paulo, SP, Brazil) and TechneScan -DTPA/AEROSOL (99mTc-DTPA/A, 15 mCi/1.5 ml with 0.5 ml ethanol; Mallinckrodt Medical, St. Louis, MO, USA), were compared in pulmonary ventilation studies in terms of total radiocounts and clearance after inhalation. An aerosol with ethanol is supposed to better distribute the radioparticles in the lungs. Twenty normal nonsmoking volunteers (10 men and 10 women), mean age of 23.2 years (range: 20 to 35 years), were studied. Images were obtained immediately and 30, 60 and 90 min after inhalation. Total and regional counts were obtained and the clearance half-lives of both lungs were determined. There was no difference in total counts between the two types of radioaerosol at any time (mean of approximately 188,000 cpm for male and female subjects at time zero in both aerosols). The highest count was obtained in the middle region of both lungs (P<0.001) with both preparations. The clearance half-life did not differ between aerosols (mean of ~80-88 min for male and female subjects for both aerosols). Small nonsignificant regional differences were observed. No differences between genders or between right and left lung were observed. 99mTc-DTPA/A generated the highest output of radioaerosol. 99mTc-DTPA with alcohol costs approximately five times more than the aerosol without alcohol. The present results show that either kind of aerosol may be adopted routinely for use in pulmonary examinations without affecting diagnosis. We suggest that the amount of 740 mBq (20 mCi) of 99mTc-DTPA in 1.5 ml saline can be used for routine examinations resulting in reduction of costs in pulmonary ventilation studies without diagnostic impairment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ventilation-perfusion SPECT with 99mTc-DTPA versus Technegas: a head-to-head study in obstructive and nonobstructive disease.

UNLABELLED Lung scintigraphy is primarily used to diagnose pulmonary embolism. Ventilation imaging is often performed using (99m)Tc-DTPA or Technegas, an ultrafine dispersion of (99m)Tc-labeled carbon. Despite the common use of these radioaerosols, they have not been compared in an intraindividual study, and not with ventilation-perfusion (V/P) SPECT. The aim of the present head-to-head study w...

متن کامل

Lung clearance of soluble radioaerosols of different molecular weights in systemic sclerosis.

Clearance rates of soluble radioaerosols of sodium pertechnetate (99mTcO4; mol wt 163) and diethylenetriaminepenta-acetate (99mTc-DTPA; mol wt 492) were determined in seven normal subjects and ten patients with systemic sclerosis affecting the lungs. Twenty millicuries (mCi) each of 99mTcO4 and 99mTc-DTPA in 5 ml saline were aerosolised and inhaled using a disposable "Blount" nebuliser on two d...

متن کامل

Spurious lung perfusion ventilation defect on planar ventilation-perfusion scan detected by SPECT imaging

Pulmonary embolism (PE) is a preventable cause of morbidity and mortality which needs prompt recognition. Ventilation-perfusion (V/Q) scan is a well-established diagnostic test for evaluation of suspected PE. We report a 32-year-old woman with history of rheumatologic disease and acute dyspnea, who was referred for V/Q scintigraphy. The planar images revealed multiple mismatched defects through...

متن کامل

Acute paraquat intoxication: using nuclear pulmonary studies to predict patient outcome.

STUDY OBJECTIVES Paraquat, a widely used herbicide, has been shown to cause severe and often fatal pulmonary fibrosis in humans and laboratory animals. Although paraquat is known to be directly cytotoxic to lung parenchyma, changes in routine lung scintigraphy results after acute paraquat intoxication have not been reported. The objective of this project was to investigate changes in lung venti...

متن کامل

Technetium-99m DTPA aerosol contamination in lung ventilation studies.

UNLABELLED Contamination of working areas by 99mTc DTPA aerosol is of concern to nuclear medicine technologists. This study sought to determine the extent of 99mTc DTPA contamination to technologists, and to localize sources of aerosol leakage so that methods could be identified that would minimize contamination. METHODS Fifty to eighty millicuries 99mTc DTPA, diluted to a volume of 4-5 ml wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas

دوره 36 10  شماره 

صفحات  -

تاریخ انتشار 2003