Popliteal artery compression: a complication of Gore-Tex anterior cruciate ligament reconstruction.

نویسندگان

  • T J Spalding
  • D J Botsford
  • M Ford
  • P H Marks
چکیده

Use of the Gore-Tex polytetrafluoroethylene (PTFE) braided ligament (W. L. Gore & Associates Inc, Flagstaff, Arizona) for reconstruction of the anterior cruciate ligament (ACL) is associated with high rates of recurrent effusion and ligament rupture (Indelicato, Pascale and Huegel 1989; Fu and Olson 1992). In addition, osteolysis in the tibial tunnel has been reported due to a histiocytic response to PTFE particles released by abrasion (Seemann and Steadman 1993). We report a case in which a cyst which formed around the femoral insertion of a ruptured Gore-Tex ligament resulted in intermittent claudication. Case report. In 1985, a 37-year-old male competitive hockey player had reconstruction of an ACL with a GoreTex PTFE prosthesis using the ‘over-the-top’ route. He returned to sport but four years later noticed increasing instability. In June 1993 he suddenly developed a cramping pain in the right calf after walking 100 yards; this settled with rest but returned on further exercise. His peripheral pulses were normal but the ankle-brachial index (ABI) was 0.7. Venography was normal. The calf claudication continued for two weeks before disappearing spontaneously and then reappearing during the next month. Femoral arteriography and Doppler wave forms were normal. A stress test produced severe cramping pain in the calf and a decrease in the ABI from 1.21 to 0.25. At this stage, his pain-free walking distance was 300 metres; he denied any altered sensation or footdrop. He was not diabetic but smoked 20 cigarettes a day. Clinical examination of the knee showed mild varus alignment with medial compartment crepitus, no evidence of function of the Gore-Tex ligament but no effusion. His lumbar spine, peripheral sensation and pulses were normal. Radiographs showed tricompartmental osteoarthritis with posterior osteophytes and CT revealed that a large cystic structure was compressing and displacing the neurovascular bundle (Fig. 1a).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anterior cruciate ligament construction using the Gore-tex ligament.

ANTERIOR CRUCIATE LIGAMENT CONSTRUCTION USING THE GORE-TEX LIGAMENT From Major B R Singer, RAMC and Group Captain M WWard,RAF Sir, Captain Bowyer and Major Matthews (1) are to be congratulated for reminding us of the serious implications of anterior cruciate ligament (ACL) injuries to a soldier's fitness and career. Their short follow-up (mean of 18 months) reflects the problems inherent in rev...

متن کامل

Anterior cruciate ligament reconstruction using the Gore-tex ligament.

Twenty two Army patients with synthetic (Gore-tex) anterior cruciate ligament (ACL) reconstructions were reviewed (mean follow up 18 months). Reconstruction appeared to abolish the pivot shift sign in all cases, but some subjective instability persisted in all but 6 patients. Outcome was also assessed by medical (PULHHEEMS) grading: 6 patients were fully fit (graded L2), 7 returned to moderate ...

متن کامل

Femoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature

 Background: A rare and devastating complication following anterior cruciate ligament (ACL) revision reconstruction is femoral fracture.    Case presentation: A 35-year old male soccer player with a history of ACL tear from the previous year ago, who underwent arthroscopic ACL reconstruction and functioned well until another similar injury caused ACL re-rupture. Revision of ACL reconstruction w...

متن کامل

Does Intravenous or Intraarticular Tranexamic Acid (TXA) Reduce Joint Bleeding Following Arthroscopic Anterior Cruciate Ligament (ACL) Reconstruction and Arthroscopic Meniscectomy? Can Intraarticular Use be Harmful to Chondrocytes?

Arthroscopic knee surgery to perform partial meniscectomy and anterior cruciate ligament (ACL) reconstruction is frequent and effective, although a possible complication is postoperative intra-articular bleeding. When this complication occurs, in addition to the associated pain, the patient usually requires an arthrocentesis to avoid loss of joint mobility. Sometimes this problem ends up associ...

متن کامل

Popliteal Artery Pseudoaneurysm after Anterior Cruciate Ligament Re-Revision Using a Rigidfix Cross Pin

Popliteal artery injury is a very rare complication of anterior cruciate ligament (ACL) reconstruction. The authors experienced a case of popliteal arterial pseudoaneurysm after re-revision of ACL reconstruction using Rigidfix for femoral tunnel fixation. Pseudoaneurysm was detected in knee magnetic resonance imaging, which caused pain, limit of motion, common peroneal nerve palsy, leg swelling...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 78 1  شماره 

صفحات  -

تاریخ انتشار 1996