Mycobacteria in water and loose deposits of drinking water distribution systems in Finland.
نویسندگان
چکیده
Drinking water distribution systems were analyzed for viable counts of mycobacteria by sampling water from waterworks and in different parts of the systems. In addition, loose deposits collected during mechanical cleaning of the main pipelines were similarly analyzed. The study covered 16 systems at eight localities in Finland. In an experimental study, mycobacterial colonization of biofilms on polyvinyl chloride tubes in a system was studied. The isolation frequency of mycobacteria increased from 35% at the waterworks to 80% in the system, and the number of mycobacteria in the positive samples increased from 15 to 140 CFU/liter, respectively. Mycobacteria were isolated from all 11 deposits with an accumulation time of tens of years and from all 4 deposits which had accumulated during a 1-year follow-up time. The numbers of mycobacteria were high in both old and young deposits (medians, 1.8 x 10(5) and 3.9 x 10(5) CFU/g [dry weight], respectively). Both water and deposit samples yielded the highest numbers of mycobacteria in the systems using surface water and applying ozonation as an intermediate treatment or posttreatment. The number and growth of mycobacteria in system waters correlated strongly with the concentration of assimilable organic carbon in the water leaving the waterworks. The densities of mycobacteria in the developing biofilms were highest at the distal sites of the systems. Over 90% of the mycobacteria isolated from water and deposits belonged to Mycobacterium lentiflavum, M. tusciae, M. gordonae, and a previously unclassified group of mycobacteria. Our results indicate that drinking water systems may be a source for recently discovered new mycobacterial species.
منابع مشابه
Hotspots for selected metal elements and microbes accumulation and the corresponding water quality deterioration potential in an unchlorinated drinking water distribution system.
Biofilm formation, loose deposit accumulation and water quality deterioration in drinking water distribution systems have been widely reported. However, the accumulation and distribution of harbored elements and microbes in the different niches (loose deposits, PVC-U biofilm, and HDPE biofilm) and their corresponding potential contribution to water quality deterioration remain unknown. This pre...
متن کاملStudy on Microbiological Quality of Rural and Urban Drinking Water in Distribution Systems of Ijroud, Zanjan in 2013-2015
Background: Providing safe drinking water has critical importance to human societies. The aim of this study was to investigate microbiological quality of drinking water in distribution system of urban and rural regions of Ijroud, in Zanjan province. Materials and Methods: In present descriptive study, the microbiological examination of drinking water was conducted in 15 facilities with...
متن کاملSurvey the Nitrate Concentration in Drinking Water Distribution Systems of Kashan County, Iran
High concentration of nitrate is a prevalent problem in water resources. Untreated wastewater due to municipal, industrial and agricultural activities is the main potential source of nitrate contamination of groundwater and surface water. The maximum permissible level of nitrate concentration has been established to be 45 mg/L by WHO and US–EPA. Health problems, such as Methemoglobinemia in bab...
متن کاملOccurrence of mycobacteria in water treatment lines and in water distribution systems.
The frequency of recovery of atypical mycobacteria was estimated in two treatment plants providing drinking water to Paris, France, at some intermediate stages of treatment. The two plants use two different filtration processes, rapid and slow sand filtration. Our results suggest that slow sand filtration is more efficient for removing mycobacteria than rapid sand filtration. In addition, our r...
متن کاملDetermination of corrosion and sedimentation potential in drinking water distribution system of khorramabad city by corrosion indices and weight loss method
Pirialam R1, Shams khorramabadi Gh2, Shahmansouri MR3, Farzadkiya M4 1. MSc in Environmental Health, Lorestan University of Medical Sciences, Khorramabad, Iran 2. Assistant Professor, Department of Environmental Health, Faculty of Health, Lorestan University of Medical Sciences, Khorramabad, Iran 3. Associate Professor, Department of Environmental Health, Faculty of Health, Isfahan University o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied and environmental microbiology
دوره 70 4 شماره
صفحات -
تاریخ انتشار 2004