[Biomechanical parameters and clinical outcomes of the Oxford Phase III unicompartmental knee replacement].

نویسندگان

  • P Kubát
  • Z Ptáček
چکیده

PURPOSE OF THE STUDY The kinematics of an intact knee joint and that of a knee replacement have been studied in many research centres. In the 1987 radiographic study, Bradley, Goodfellow and O'Connor reported the movement of a polyethylene insert in patients with unicompartmental Oxford knee replacement. Views with the knee at full extension and 90° of flexion were obtained and the movement of the meniscal bearings over this range of flexion was measured. The bearings were found to move backwards on the tibia through an average distance of 4.4 mm in all 16 patients. This measurement was in agreement with the then valid concept of knee biomechanics and a roll-back phenomenon. However, our observations had not always agreed with the results of these authors, but gave an impetus for a detailed evaluation of our own patient group. The aim of the study was to evaluate the dynamic relationship between the components of a unicompartmental Oxford knee replacement and elucidate it with the use of recent information from the field of biomechanics. A relationship of the obtained kinematic values to clinical outcomes was also investigated. Answers to the following hypotheses were sought: Would our results be in agreement with the British authors' findings? Would clinical outcomes depend on the kinematic properties of knee replacements? MATERIAL AND METHODS The group comprised 33 patients, 23 women and 10 men. They all had replacement of the medial compartment of the knee. The construction of the unicompartmental Oxford Phase III knee replacement enabled us to locate the centre of rotation of the medial femoral condyle in relation to the tibial component at flexion and extension of the knee, using radiography. The patients were examined in a supine position with the knee at full extension, and subsequently views of the knee were obtained at 80°-90° flexion in accordance with the method used by the British authors. The clinical findings of knee joints were assessed using the American Knee Society (AKS) scoring system (Insall et al.). Pain was rated on the Visual Analogue Scale (VAS). The results were statistically evaluated with the t-test and Chi-square test. RESULTS On moving the knee from extension to flexion, movement of the polyethylene insert ventrally by an average of 3.4 mm in relation to the tibia was recorded, i.e., "paradoxical" ventral translocation. In the patients with insert movement less than or equal to 3 mm, the average AKS score was 89 points, in those with movement over 3 mm it was 87 points. The average functional scores were 87 and 83 points in the patients with movement less than 3 mm and more than 3 mm, respectively. The average VAS score was 1.55 in the former and 1.18 in the latter. DISCUSSION The unicompartmental Oxford Phase III knee replacement substitutes a flexion femoral facet and eliminates the role of an extension femoral facet. This is the reason why, at knee extension between -5° and +20°, the centre of rotation of the medial femoral condyle is in the centre of the flexion facet and not in that of the extension facet. When the stabilising functions of the extension tibial facet in the ventral direction and of the dorsal part of the insert in the dorsal direction are missing, the position of the contact surface centre becomes much dependent also on the strength and direction of external forces acting in the knee joint vicinity. CONCLUSIONS The kinematic parameters of the unicompartmental Oxford Phase III knee replacement investigated in our group differed from the findings of the British authors. However, neither the magnitude nor the direction of movement had any effect on the clinical outcome of knee arthroplasty.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The young patient and the medial unicompartmental knee replacement.

PURPOSE Younger patients with unicompartmental degenerative knee joint diseases present a therapeutic dilemma. The purpose of this study is to evaluate the long-term results of the Oxford phase III unicompartmental knee replacement through a minimally invasive approach in the young patient. METHODS We have studied a total of 51 patients (59 interventions) who underwent the Oxford Phase III Un...

متن کامل

Early Results of Oxford Mobile Bearing Medial Unicompartmental Knee Replacement (UKR) with the Microplasty Instrumentation: An Indian Experience

Background: Oxford medial unicompartmental knee replacement (UKR) is indicated in patients with anteromedialosteoarthritis (AMOA) of the knee. Microplasty (MP) instrumentation was introduced in 2012 as an improvement overphase 3 instrumentation. Advantages of this instrumentation include conservative tibial cut, decreased tibial re-cut rateand improved component alignment. We report the results...

متن کامل

Cemented versus Uncemented Oxford Unicompartmental Knee Arthroplasty: Is There a Difference?

Purpose. The use of uncemented unicompartmental knee prostheses has recently increased. However, few studies on the outcomes of uncemented unicompartmental knee prostheses have been performed. The purpose of this study was to compare the outcomes of cemented and uncemented Oxford unicompartmental knee arthroplasty. Materials and Methods. This retrospective observational study evaluated the clin...

متن کامل

Medial Unicompartmental Osteoarthritis (MUO) of the Knee: Unicompartmental Knee Replacement (UKR) or Total Knee Replacement (TKR)

The aim of this review article is to analyze the clinical effectiveness of total knee replacement (TKR) compared to unicompartmental knee replacement (UKR) in patients with medial unicompartmental osteoarthritis (MUO) in terms of survival rates, revision rates and postoperative complications. The search engine was MedLine. The keywords used were: medial knee osteoarthritis. Three thousand and n...

متن کامل

Ten- to 15-year results of the Oxford Phase III mobile unicompartmental knee arthroplasty

AIMS The interest in unicompartmental knee arthroplasty (UKA) for medial osteoarthritis has increased rapidly but the long-term follow-up of the Oxford UKAs has yet to be analysed in non-designer centres. We have examined our ten- to 15-year clinical and radiological follow-up data for the Oxford Phase III UKAs. PATIENTS AND METHODS Between January 1999 and January 2005 a total of 138 consecu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca

دوره 78 4  شماره 

صفحات  -

تاریخ انتشار 2011