Extracorporeal high intensity focused ultrasound for renal tumours: a 3-year follow-up.

نویسندگان

  • Robert W Ritchie
  • Tom Leslie
  • Rachel Phillips
  • Feng Wu
  • Rowland Illing
  • Gail ter Haar
  • Andrew Protheroe
  • David Cranston
چکیده

OBJECTIVE To determine whether primary extracorporeal high-intensity focused ultrasound (HIFU) is safe, feasible and effective for managing small renal tumours. PATIENTS AND METHODS Although surgery currently remains the standard treatment for localized renal cell carcinoma (RCC), the increasing incidence of small renal cancers has led to a shift towards nephron-sparing surgery, with associated morbidity in 20-25% of cases, and minimally invasive ablative therapies present an alternative management. HIFU results in 'trackless' homogenous tissue ablation and when administered via an extracorporeal device, is entirely noninvasive. The study comprised 17 patients (mean tumour size 2.5 cm) with radiologically suspicious renal tumours who underwent extracorporeal HIFU using the Model-JC System (Chongqing HAIFU™, China), under general anaesthesia with one overnight hospital stay. Real-time diagnostic ultrasonography was used for targeting and monitoring. Patients were followed with a clinical review and gadolinium-enhanced magnetic resonance imaging at 12 days and every 6 months for a mean of 36 months. The outcomes measures were patient morbidity and oncological efficacy of HIFU treatment. RESULTS Of the 17 patients, 15 were treated according to protocol; two procedures were abandoned due to intervening bowel. There were no major complications related to HIFU. Radiological evidence of ablation was apparent at 12 days in seven of the 15 patients. Before the 6-month follow-up one patient had surgery due to persisting central enhancement. Fourteen patients were evaluated at the 6-month follow-up; eight tumours had involuted (mean 12% decrease in tumour area). Four patients had irregular enhancement on imaging and had alternative therapies. Ten patients remain on follow-up at a mean (range) of 36 (14-55) months after HIFU (mean 30% decrease in tumour area). There was central loss of enhancement in all. CONCLUSIONS Renal HIFU achieves stable lesions in two-thirds of patients, with minimal morbidity, and might be appropriate in selected cases. Further trials with accurate histological follow-up are essential to fully evaluate this novel technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extracorporeal high intensity focused ultrasound ablation in the treatment of 1038 patients with solid carcinomas in China: an overview.

The ideal treatment of localized cancer should directly cause an irreversible and complete death of tumor cells without damage to surrounding normal tissue. High intensity focused ultrasound (HIFU) is such a potential treatment, which induces a complete coagulative necrosis of a tumor at depth through the intact skin. The idea that using an extracorporeal source of therapeutic ultrasound was in...

متن کامل

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

Extracorporeal Focused Ultrasound Lithotripsy - Cavitation Control Lithotripsy - 4 Continued on page

Introduction Ultrasound is widely applied in the clinical field today, such as ultrasound contrast agent imaging, High Intensity Focused Ultrasound (HIFU), Extracorporeal Lithotripsy, sonodynamic therapy. Some of these have a close relation to the dynamic behavior of micro bubbles and that of a bubble cloud. In an ultrasound imaging, micro bubbles are used as contrast agents. Extracorporeal Foc...

متن کامل

Laparoscopic high-intensity focused ultrasound for renal tumours: a proof of concept study.

UNLABELLED Study Type--Therapy (case series) Level of Evidence What's known on the subject? and What does the study add? Renal cancer is increasingly diagnosed when tumours are small and asymptomatic, during routine abdominal imaging. Whilst surgery is an effective and potentially curative option, it carries a significant risk of complications. Recent work suggests that thermally ablative thera...

متن کامل

A novel approach to energy ablative therapy of small renal tumours: laparoscopic high-intensity focused ultrasound.

OBJECTIVE High-intensity focused ultrasound (HIFU) permits targeted homogeneous ablation of tissue. The objective of this phase 1 study was to evaluate the feasibility of HIFU ablation of small renal tumours under laparoscopic control. PATIENTS AND METHODS Ten kidneys with solitary renal tumours were treated with a newly developed 4.0 MHz laparoscopic HIFU probe. In the first two patients wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BJU international

دوره 106 7  شماره 

صفحات  -

تاریخ انتشار 2010