Soft-gated accelerated Cartesian 4D flow imaging with intrinsic navigation

نویسندگان

  • Joseph Y Cheng
  • Marcus T Alley
  • Tao Zhang
  • Peng Lai
  • Jonathan I Tamir
  • Martin Uecker
  • John M Pauly
  • Michael Lustig
  • Shreyas S Vasanawala
چکیده

Joseph Y Cheng, Marcus T Alley, Tao Zhang, Peng Lai, Jonathan I Tamir, Martin Uecker, John M Pauly, Michael Lustig, and Shreyas S Vasanawala Electrical Engineering, Stanford University, Stanford, CA, United States, Radiology, Stanford University, Stanford, CA, United States, Global Applied Science Laboratory, GE Healthcare, Menlo Park, CA, United States, Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, United States

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac 4D phase-contrast CMR at 9.4 T using self-gated ultra-short echo time (UTE) imaging

BACKGROUND Time resolved 4D phase contrast (PC) cardiovascular magnetic resonance (CMR) in mice is challenging due to long scan times, small animal ECG-gating and the rapid blood flow and cardiac motion of small rodents. To overcome several of these technical challenges we implemented a retrospectively self-gated 4D PC radial ultra-short echo-time (UTE) acquisition scheme and assessed its perfo...

متن کامل

Feasibility of 4D flow MR imaging of the brain with either Cartesian y-z radial sampling or k-t SENSE: comparison with 4D Flow MR imaging using SENSE.

PURPOSE A drawback of time-resolved 3-dimensional phase contrast magnetic resonance (4D Flow MR) imaging is its lengthy scan time for clinical application in the brain. We assessed the feasibility for flow measurement and visualization of 4D Flow MR imaging using Cartesian y-z radial sampling and that using k-t sensitivity encoding (k-t SENSE) by comparison with the standard scan using SENSE. ...

متن کامل

Rapid flow assessment of congenital heart disease using high spatio-temporal gated spiral phase-contrast MR

Purpose Many sick adults and children are unable to perform long breath-holds required for conventional, Cartesian phase-contrast (PC) sequences. Using a prospectivelytriggered spiral PCMR sequence accelerated with sensitivity encoding (SENSE), it should be possible to achieve high resolution PCMR data in a short breath-hold. The aim of this study was to compare flow volumes measured using: a) ...

متن کامل

Benefits and Pitfalls in the Use of Contrast Agents in 4D Flow Imaging

Introduction Recent advances in hardware and the emergence of various accelerated techniques have facilitated the use of 4D flow imaging for the simultaneous assessment of vascular anatomy and cine velocity fields. However, further advances in decreasing scan time and/or improving spatial resolution and coverage are complicated by the limited signal-to-noise ratio (SNR). Bock et al. [1] demonst...

متن کامل

Evaluation of Flow Research Promises: What can we expect in the Future?

Methods Over recent years, advances in hardware, sequence design, and image reconstruction have facilitated accelerated cardiovascular imaging. Here we will discuss the technical background and research promises of selected new developments in flow sensitive MRI that can potentially have a significant impact on patient care. In particular, the topics of (1) realtime PC MR imaging, (2) ultrashor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014