Soft-gated accelerated Cartesian 4D flow imaging with intrinsic navigation
نویسندگان
چکیده
Joseph Y Cheng, Marcus T Alley, Tao Zhang, Peng Lai, Jonathan I Tamir, Martin Uecker, John M Pauly, Michael Lustig, and Shreyas S Vasanawala Electrical Engineering, Stanford University, Stanford, CA, United States, Radiology, Stanford University, Stanford, CA, United States, Global Applied Science Laboratory, GE Healthcare, Menlo Park, CA, United States, Electrical Engineering and Computer Sciences, University of California, Berkeley, CA, United States
منابع مشابه
Cardiac 4D phase-contrast CMR at 9.4 T using self-gated ultra-short echo time (UTE) imaging
BACKGROUND Time resolved 4D phase contrast (PC) cardiovascular magnetic resonance (CMR) in mice is challenging due to long scan times, small animal ECG-gating and the rapid blood flow and cardiac motion of small rodents. To overcome several of these technical challenges we implemented a retrospectively self-gated 4D PC radial ultra-short echo-time (UTE) acquisition scheme and assessed its perfo...
متن کاملFeasibility of 4D flow MR imaging of the brain with either Cartesian y-z radial sampling or k-t SENSE: comparison with 4D Flow MR imaging using SENSE.
PURPOSE A drawback of time-resolved 3-dimensional phase contrast magnetic resonance (4D Flow MR) imaging is its lengthy scan time for clinical application in the brain. We assessed the feasibility for flow measurement and visualization of 4D Flow MR imaging using Cartesian y-z radial sampling and that using k-t sensitivity encoding (k-t SENSE) by comparison with the standard scan using SENSE. ...
متن کاملRapid flow assessment of congenital heart disease using high spatio-temporal gated spiral phase-contrast MR
Purpose Many sick adults and children are unable to perform long breath-holds required for conventional, Cartesian phase-contrast (PC) sequences. Using a prospectivelytriggered spiral PCMR sequence accelerated with sensitivity encoding (SENSE), it should be possible to achieve high resolution PCMR data in a short breath-hold. The aim of this study was to compare flow volumes measured using: a) ...
متن کاملBenefits and Pitfalls in the Use of Contrast Agents in 4D Flow Imaging
Introduction Recent advances in hardware and the emergence of various accelerated techniques have facilitated the use of 4D flow imaging for the simultaneous assessment of vascular anatomy and cine velocity fields. However, further advances in decreasing scan time and/or improving spatial resolution and coverage are complicated by the limited signal-to-noise ratio (SNR). Bock et al. [1] demonst...
متن کاملEvaluation of Flow Research Promises: What can we expect in the Future?
Methods Over recent years, advances in hardware, sequence design, and image reconstruction have facilitated accelerated cardiovascular imaging. Here we will discuss the technical background and research promises of selected new developments in flow sensitive MRI that can potentially have a significant impact on patient care. In particular, the topics of (1) realtime PC MR imaging, (2) ultrashor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2014