Improved fat suppression using multipeak reconstruction for IDEAL chemical shift fat-water separation: application with fast spin echo imaging.
نویسندگان
چکیده
PURPOSE To evaluate and quantify improvements in the quality of fat suppression for fast spin-echo imaging of the knee using multipeak fat spectral modeling and IDEAL fat-water separation. MATERIALS AND METHODS T(1)-weighted and T(2)-weighted fast spin-echo sequences with IDEAL fat-water separation and two frequency-selective fat-saturation methods (fat-selective saturation and fat-selective partial inversion) were performed on 10 knees of five asymptomatic volunteers. The IDEAL images were reconstructed using a conventional single-peak method and precalibrated and self-calibrated multipeak methods that more accurately model the NMR spectrum of fat. The signal-to-noise ratio (SNR) was measured in various tissues for all sequences. Student t-tests were used to compare SNR values. RESULTS Precalibrated and self-calibrated multipeak IDEAL had significantly greater suppression of signal (P < 0.05) within subcutaneous fat and bone marrow than fat-selective saturation, fat-selective partial inversion, and single-peak IDEAL for both T(1)-weighted and T(2)-weighted fast spin-echo sequences. For T(1)-weighted fast spin-echo sequences, the improvement in the suppression of signal within subcutaneous fat and bone marrow for multipeak IDEAL ranged between 65% when compared to fat-selective partial inversion to 86% when compared to fat-selectivesaturation. For T2-weighted fast spin-echo sequences, the improvement for multipeak IDEAL ranged between 21% when compared to fat-selective partial inversion to 81% when compared to fat-selective saturation. CONCLUSION Multipeak IDEAL fat-water separation provides improved fat suppression for T(1)-weighted and T(2)-weighted fast spin-echo imaging of the knee when compared to single-peak IDEAL and two widely used frequency-selected fat-saturation methods.
منابع مشابه
Comparison of IDEAL, MultiPeak IDEAL and Fat-Saturated FSE for Imaging of Osteoarthritis (OA) Knee Patients: Initial Clinical Experience
INTRODUCTION Iterative Decomposition of Water and Fat with Echo Asymmetry and Least-Squares Estimation (IDEAL) is a promising MRI technique for robust fat and water separation (1). It was found with higher fluid/cartilage contrast-to-noise ratio efficiency and fat-suppression quality than FSE imaging in ankle. The goal of this study is to assess image quality, fat suppression and fat-water sepa...
متن کاملIDEAL at 7T in Mice Using Asymmetric Spin Echo and Gradient Echo Acquisitions
An asymmetric spin echo (aSE) technique was developed to produce uniform, robust fat-water separation in mice at 7T using Iterative Decomposition of Water and Fat with Echo Asymmetry and Least-squares estimation method (IDEAL). The aSE technique had superior image quality as compared to gradient echo IDEAL estimation. Both the spin echo and gradient echo IDEAL techniques resulted in more accura...
متن کاملCompressed sensing for chemical shift-based water-fat separation.
Multi echo chemical shift-based water-fat separation methods allow for uniform fat suppression in the presence of main field inhomogeneities. However, these methods require additional scan time for chemical shift encoding. This work presents a method for water-fat separation from undersampled data (CS-WF), which combines compressed sensing and chemical shift-based water-fat separation. Undersam...
متن کاملIterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) fast spin-echo imaging of the ankle: initial clinical experience.
OBJECTIVE Reliable, uniform fat suppression is important. Multiple approaches currently exist, many of which suffer from either suboptimal signal-to-noise ratio (SNR), or the inability to obtain consistent fat suppression around the ankle joint. Our purpose was to test iterative decomposition of water and fat with echo asymmetry and the least-squares estimation (IDEAL) method in combination wit...
متن کاملIterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): application with fast spin-echo imaging.
Chemical shift based methods are often used to achieve uniform water-fat separation that is insensitive to Bo inhomogeneities. Many spin-echo (SE) or fast SE (FSE) approaches acquire three echoes shifted symmetrically about the SE, creating time-dependent phase shifts caused by water-fat chemical shift. This work demonstrates that symmetrically acquired echoes cause artifacts that degrade image...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 29 2 شماره
صفحات -
تاریخ انتشار 2009