Development of a direct competitive microcystin immunoassay of broad specificity.

نویسندگان

  • M G Weller
  • A Zeck
  • A Eikenberg
  • S Nagata
  • Y Ueno
  • R Niessner
چکیده

produced by several cyanobacterial species.1 The toxicological mechanism is mainly based on a strong inhibition of protein phosphatases, which may lead to severe—sometimes lethal— liver damage.2,3 In addition, microcystins are considered to be tumor promotors. Hence, the control of microcystins is critical for water quality. Recent publications have stated that about 90 microcystins and nodularins have already been characterized.4,5 Only a few microcystins and one nodularin are available as standard compounds. There is some concern that analytical methods for the detection of hepatotoxic peptides may overlook toxins and perhaps cause a significant number of false negative samples. This applies to instrumental techniques (e.g., HPLC, MS) as well as for immunochemical assays. Only the mouse bioassay is considered to give a relatively definite answer,6 however, this test for acute toxicity is relatively insensitive, and criticism has been expressed against these crude animal tests. Several immunoassays have been developed for the analysis of microcystins.7–16 Unfortunately, none of them have gained widespread application, which may be caused by insufficient sensitivity, unfavorable cross-reactivities and difficult availability. Most desirable would be an immunoassay of broad reactivity towards all microcystins,6 allowing a measurement of the sum concentration of these compounds, which would be a useful index for regulatory purposes. A known monoclonal antibody9 against microcystin-LR (MC-LR) was used in this study. The antibody (clone M8H5) had been generated by immunization with a BSA-microcystin-LR conjugate, prepared by coupling the carboxylic groups of microcystin-LR to the protein with a water-soluble carbodiimide (conjugation density MC-LR/BSA 1.3 mol/mol). Because MC-LR has two carboxylic groups available for conjugation (see Fig. 1), the immunogen is not structurally unambiguous. Most characteristics of M8H5 support the notion that the effective conjugation site was at amino acid (3), not at (6). If (6) would have been the conjugation site, one should expect a larger influence of the arginine at position (4). In addition, the loss of a methyl group at (3) seems to be of minor importance. Other clones isolated in parallel to M8H5 showed relatively similar cross-reactivity patterns.9 Although the antibody M8H5 showed high affinity to the antigen (k = 1.3 × 1010 L/mol), the crossreactivity pattern of M8H5 was not broad enough in the previously tested assay formats. The generation of new antibodies17 may solve such selectivity problems. As shown in many papers, the selectivity of antibodies can be considerably influenced by the orientation of the hapten during immunization. If broad reactivity is desired, the common substructure must be placed at the “outer” side, which is located opposite to the conjugation site to the protein carrier. This approach probably works better with large antigens/haptens, with extended common epitopes. In other cases, all parts of the analyte influence the binding by the antibody, and consequently the cross-reactivity pattern is uneven. However, it should be 1445 ANALYTICAL SCIENCES DECEMBER 2001, VOL. 17 2001 © The Japan Society for Analytical Chemistry

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Colorimetric immuno-protein phosphatase inhibition assay for specific detection of microcystins and nodularins of cyanobacteria.

A novel immunoassay was developed for specific detection of cyanobacterial cyclic peptide hepatotoxins which inhibit protein phosphatases. Immunoassay methods currently used for microcystin and nodularin detection and analysis do not provide information on the toxicity of microcystin and/or nodularin variants. Furthermore, protein phosphatase inhibition-based assays for these toxins are not spe...

متن کامل

Determination of microcystin-LR in surface water by a magnetic bead-based colorimetric immunoassay using antibody-conjugated gold nanoparticles

Herein we describe the development of a homogeneous competitive colorimetric immunoassay using antigen-functionalized magnetic beads (MBs) and antibody-immobilized gold nanoparticles (AuNPs) combined with the established gold staining method for the determination of microcystin-leucinearginine (MC-LR) in surface water. Solid phase extraction proved to be the most beneficial sample preparation m...

متن کامل

Generic microcystin immunoassay based on monoclonal antibodies against Adda.

A monoclonal antibody (clone AD4G2) was generated against a common part of microcystins and nodularins, the unusual amino acid Adda [(2S,3S,8S,9S)-3-amino-9-methoxy-2,6,8-trimethyl-10-phenyldeca-4E,6E-dienoic acid]. A direct competitive ELISA based on this antibody was developed and the cross-reactivity pattern was measured. Different toxins showed a very similar response. The assay provides th...

متن کامل

Rapid and Highly Sensitive Non-Competitive Immunoassay for Specific Detection of Nodularin

Nodularin (NOD) is a cyclic penta-peptide hepatotoxin mainly produced by Nodularia spumigena, reported from the brackish water bodies of various parts of the world. It can accumulate in the food chain and, for safety reasons, levels of NOD not only in water bodies but also in food matrices are of interest. Here, we report on a non-competitive immunoassay for the specific detection of NOD. A pha...

متن کامل

Cloning and plant‐based production of antibody MC10E7 for a lateral flow immunoassay to detect [4‐arginine]microcystin in freshwater

Antibody MC10E7 is one of a small number of monoclonal antibodies that bind specifically to [Arg4]-microcystins, and it can be used to survey natural water sources and food samples for algal toxin contamination. However, the development of sensitive immunoassays in different test formats, particularly user-friendly tests for on-site analysis, requires a sensitive but also cost-effective antibod...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 17 12  شماره 

صفحات  -

تاریخ انتشار 2001