Development and test of a GEM-based TEPC for neutron protection dosimetry.

نویسندگان

  • C-K Chris Wang
  • Marat Seidaliev
  • Anant Mandapaka
چکیده

A novel tissue-equivalent proportional counter (TEPC) based on a gas electron multiplier (GEM) for measuring H*(10) for neutrons was designed and constructed. The pulse height spectra (PHS) of two different neutron sources (a 252Cf source and a AmBe source) were measured using the new TEPC. The measurements were made with the TEPC filled with two different gases (10P gas and a propane-based tissue-equivalent gas) at various pressures. A computer simulation of the new TEPC, based on the Monte Carlo method, was performed to obtain the PHS for the two neutron sources. It is shown that the experimental results agree well with the simulation results for both 252Cf and AmBe neutron sources. Several outstanding problems are discussed and suggestions are made to make the GEM-based TEPC a practical neutron rem meter. The potential advantage of this novel neutron rem meter would be its low weight and compactness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and simulation of a GEM-based TEPC as a neutron REM meter.

A new plate-like tissue equivalent proportional counter (TEPC) based on the gas electron multiplier (GEM) is being developed for use as a neutron rem meter. The advantage of a plate-like TEPC over a conventional spherical TEPC is that several of the plate-like TEPCs can be stacked together as one unit to increase sensitivity to neutrons. A GEM-based TEPC consists of four layers of materials in ...

متن کامل

Measurement of the neutron fluence and dose spectra using an extended bonner sphere and a tissue-equivalent proportional counter.

A conventional Bonner Sphere (BS) set consisting of six polyethylene spheres was modified to enhance its response to a high-energy neutron by putting a lead shell inside a polyethylene moderator. The response matrix of an extended BS was calculated using the MCNPX code and calibrated using a 252Cf neutron source. In order to survey the unknown photon and neutron mixed field, a spherical tissue ...

متن کامل

Microdosimetric Measurements with a GEM-TEPC with 62 AMeV Carbon Ions

The microdosimetric characterization represents a useful method for the quality assessment of hadron beams [1,2]. These distributions can be measured by means of Tissue Equivalent Proportional Counters (TEPCs) [3]. Besides, the possibility of performing dosimetry and quality assessment at the same time allows a detailed picture of the physical properties of clinical beams and permits the invest...

متن کامل

Galactic and solar radiation exposure to aircrew during a solar cycle.

An on-going investigation using a tissue-equivalent proportional counter (TEPC) has been carried out to measure the ambient dose equivalent rate of the cosmic radiation exposure of aircrew during a solar cycle. A semi-empirical model has been derived from these data to allow for the interpolation of the dose rate for any global position. The model has been extended to an altitude of up to 32 km...

متن کامل

An investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy

Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Health physics

دوره 94 5  شماره 

صفحات  -

تاریخ انتشار 2008