RATIONALE Determination of non-exchangeable hydrogen isotopic compositions (δ2 H values) of bulk complex organic materials is difficult due to uncontrolled H isotope exchange between the organic material and ambient water vapor. A number of calibration keratinous materials with carefully measured hydrogen isotopic compositions of the non-exchangeable fraction were proposed to enable stable isotope laboratories to normalize their 2 H measurements. However, it was recently reported that high-temperature carbon-reactor methods for measuring the hydrogen isotopic composition of nitrogenous organic materials is biased by the production of HCN in the reactor. As a result, the reported values of these calibration materials needed to be re-evaluated. METHODS We evaluated the non-exchangeable δ2 HVSMOW values of keratins EC1 (CBS) and EC2 (KHS), USGS hair standards, and a range of other nitrogenous widely used organic laboratory calibration materials (collagen and chitin) using pre-treatment with a preparation device designed to eliminate residual moisture and quantify exchangeable H. RESULTS The revised non-exchangeable δ2 HVSMOW values of EC-1 (CBS) and EC-2 (KHS) keratin standard materials were -157.0 ± 0.9 and -35.3 ± 1.1 ‰, respectively. The revised values of USGS42 and USGS43 were -72.2 ± 0.9 and -44.2 ± 1.0 ‰, respectively, in excellent agreement with previous results. CONCLUSIONS For routine H isotope analyses, with proper sample pre-treatment, we show that the Comparative Equilibration approach can provide accurate and reproducible non-exchangeable δ2 H values among laboratories regardless of the reactor type used. © 2017 Her Majesty the Queen in Right of Canada Rapid Communications in Mass Spectrometry © 2017 John Wiley & Sons Ltd. Reproduced with the permission of the Environment and Climate Change Canada.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A test of comparative equilibration for determining non-exchangeable stable hydrogen isotope values in complex organic materials.

Comparative equilibration has been proposed as a methodological approach for determining the hydrogen isotopic composition (deltaD) of non-exchangeable hydrogen in complex organic materials, from feathers to blood and soils. This method depends on using homogenized standards that have been previously calibrated for their deltaD values of non-exchangeable H, that are compositionally similar to u...

متن کامل

Calling all archaeologists: guidelines for terminology, methodology, data handling, and reporting when undertaking and reviewing stable isotope applications in archaeology

Stable isotope analysis has been utilized in archaeology since the 1970s, yet standardized protocols for terminology, sampling, pretreatment evaluation, calibration, quality assurance and control, data presentation, and graphical or statistical treatment still remain lacking in archaeological applications. Here, we present recommendations and requirements for each of these in the archaeological...

متن کامل

Provenancing of unidentified corpses by stable isotope techniques - presentation of case studies.

Stable isotope methods can be used to determine the provenance of unidentified corpses. Body tissue materials such as teeth, bone, hair and nail taken from mortal remains provide information of different time periods of an individuals' life from childhood to death. Tissues of newborns contain provenance information of different time periods during pregnancy of the child's mother. The results of...

متن کامل

Bio-gold Nanoparticle Synthesis by Metalophilic Bacterium Cupriavidus necator

Background and Aims: Gold nanoparticles have potential applications in the areas of medicine, target drug delivery, cancer diagnosis and therapy, electronic, etc. Recently, biological system is considered as an environmental friendly method for synthesis of stable nanoparticles. Methods: We demonstrated a biological system for formation of stable gold nanoparticle by using Cupriavidus necator w...

متن کامل

A gravimetric K2OsCl6 standard: Application to precise and accurate Os spike calibration

The Re-Os isotopic system is currently limited as a chronometer because of the lack of accurate gravimetric standards for Os spike calibration and uncertainty of the Re half-life, which is also dependent on the accuracy of Os spike calibration. We demonstrate that the concentration of an Os spike can be calibrated accurately to 60.2%. The accuracy of this calibration was achieved by using a hig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rapid communications in mass spectrometry : RCM

دوره 31 14  شماره 

صفحات  -

تاریخ انتشار 2017