Dental Splint Fabrication for Prospective Motion Correction in Ultrahigh-Field MR Imaging
نویسندگان
چکیده
For prospective motion correction in ultrahigh-field magnetic resonance imaging, optical tracking is employed by fixating a tailored dental splint on the subject’s upper jaw. However, producing such dental splints is cumbersome and exposes subjects to significant discomfort due to the required dental cast preparation. To catalyze the production of these custom-made splints, we propose a semi-automated workflow.By retrospectively digitizing dental casts of five subjects using a 3D laser scanner, we virtually graft the dental splints and, once visually analyzed and approved, they are fabricated by a 3D printer.This process increases subject comfort and reduces the preparation time.
منابع مشابه
T1-weighted in vivo human whole brain MRI dataset with an ultrahigh isotropic resolution of 250 μm
We present an ultrahigh resolution in vivo human brain magnetic resonance imaging (MRI) dataset. It consists of T1-weighted whole brain anatomical data acquired at 7 Tesla with a nominal isotropic resolution of 250 μm of a single young healthy Caucasian subject and was recorded using prospective motion correction. The raw data amounts to approximately 1.2 TB and was acquired in eight hours tota...
متن کاملProspective Motion Correction with Stereoscopic Optical Tracking at 7T
INTRODUCTION Artifacts caused by motion during the image acquisition are a well known problem at 1.5T and 3T. In high field systems such as 7T the available signal to noise ratio leads to potentially higher resolution than in systems with lower field. Unfortunately higher resolution requires longer acquisition times without patient motion. Therefore an increased need for motion correction exist...
متن کاملMR-based and Optical Prospective Motion Correction for High Resolution DWI with RS-EPI
Introduction: Recently, multiple approaches have been proposed to perform motion correction for diffusion imaging using optical tracking with cameras [1,2] or using MR-based methods which perform real-time registration between volumes [3-5]. In this study, we demonstrate the application of and compare both optical and MR-based motion correction to high-resolution diffusion-weighted imaging usin...
متن کاملCombined Prospective Rigid-Body Motion Correction with Retrospective Non-Rigid Distortion Correction for EPI
Introduction: Prospective real-time motion correction, where the scan-plane orientation is dynamically updated to track with the subject's head during an MRI scan, is becoming increasingly popular (1-7). While these methods focus on compensating for bulk rigid-body motion, a secondary effect of head motion is non-rigid-body image distortion caused by changes in the effective shim within the bra...
متن کاملAn adaptive MR-compatible lens
Introduction We present an MR-compatible adaptive membrane lens, which is integrated into a wide-angle objective to form part of an optical tracking system. This work is motivated by the need for optical head tracking devices for use in prospective motion correction [1], but an alternative application could be high-resolution eye tracking for fMRI. The challenge for in-bore cameras is the limit...
متن کامل