Quantifying the degradation of degradable implants and bone formation in the femoral condyle using micro-CT 3D reconstruction
نویسندگان
چکیده
Degradation limits the application of magnesium alloys, and evaluation methods for non-traumatic in vivo quantification of implant degradation and bone formation are imperfect. In the present study, a micro-arc-oxidized AZ31 magnesium alloy was used to evaluate the degradation of implants and new bone formation in 60 male New Zealand white rabbits. Degradation was monitored by weighing the implants prior to and following implantation, and by performing micro-computed tomography (CT) scans and histological analysis after 1, 4, 12, 24, 36, and 48 weeks of implantation. The results indicated that the implants underwent slow degradation in the first 4 weeks, with negligible degradation in the first week, followed by significantly increased degradation during weeks 12-24 (P<0.05), and continued degradation until the end of the 48-week experimental period. The magnesium content decreased as the implant degraded (P<0.05); however, the density of the material exhibited almost no change. Micro-CT results also demonstrated that pin volume, pin mineral density, mean 'pin thickness', bone surface/bone volume and trabecular separation decreased over time (P<0.05), and that the pin surface area/pin volume, bone volume fraction, trabecular thickness, trabecular number and tissue mineral density increased over time (P<0.05), indicating that the number of bones and density of new bone increased as magnesium degraded. These results support the positive effect of magnesium on osteogenesis. However, from the maximum inner diameter of the new bone loop and diameter of the pin in the same position, the magnesium alloy was not capable of creating sufficient bridges between the bones and biomaterials when there were preexisting gaps. Histological analyses indicated that there were no inflammatory responses around the implants. The results of the present study indicate that a micro-arc-oxidized AZ31 magnesium alloy is safe in vivo and efficiently degraded. Furthermore, the novel bone formation increased as the implant degraded. The findings concluded that micro-CT, which is useful for providing non-traumatic, in vivo, quantitative and precise data, has great value for exploring the degradation of implants and novel bone formation.
منابع مشابه
Micro Computed Tomography Analysis of Magnesium Screw Degradation & Bone Regeneration
INTRODUCTION 6.3 million cases of bone trauma happen each year in the US alone [1]. In a majority of these cases, permanent fixation implants using titanium plates and screws are used as a remedy, but they do have their drawbacks. Some of these disadvantages include bone wear and degradation, resulting in the implant to become loose. They also present a prime site for possible infection [2]. An...
متن کاملFemoral Condyle Fracture during Anterior Cruciate Ligament Reconstruction
Dear Editor,We have greatly enjoyed reading the case report entitled “‘Femoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature in the issue of Arch Bone Jt Surg. 2015;3(2) with great interest. We would like to commend the authors for their detailed and valuable work. Although various case reports have described postoperative ...
متن کاملFemoral Condyle Fracture during Revision of Anterior Cruciate Ligament Reconstruction: Case Report and a Review of Literature
Background: A rare and devastating complication following anterior cruciate ligament (ACL) revision reconstruction is femoral fracture. Case presentation: A 35-year old male soccer player with a history of ACL tear from the previous year ago, who underwent arthroscopic ACL reconstruction and functioned well until another similar injury caused ACL re-rupture. Revision of ACL reconstruction w...
متن کاملSkeletal Tuberculosis Presenting as a Small Cystic Lesion in the Medial Femoral Condyle
Skeletal tuberculosis is an unusual disease involving bone and joints and it may have different manifestations. This report introduces a 25-year-old woman suffering from chronic knee pain without any response to conservative treatments for one year. X-ray was normal but CT-scan and MRI indicated a small lesion in medial condyle of the femur. The patient underwent percutaneous CT-guided biopsy...
متن کاملInfluences of reconstruction and attenuation correction in brain SPECT images obtained by the hybrid SPECT/CT device: evaluation with a 3‐dimensional brain phantom
Objective: The aim of this study was to evaluate the influences of reconstruction and attenuation correction on the differences in the radioactivity distributions in 123I brain SPECT obtained by the hybrid SPECT/CT device. Methods: We used the 3-dimensional (3D) brain phantom, which imitates the precise structure of gray mater, white matter and bone regions. It was filled with 123I solution (20...
متن کامل