Gentamicin release from old cement during revision hip arthroplasty.

نویسندگان

  • J W Powles
  • R F Spencer
  • A M Lovering
چکیده

Bone cement containing gentamicin may release antibiotic when fractured during revision operations. Tissue samples taken during surgery may be contaminated by gentamicin and give inaccurate microbiological assessment. We studied five patients in whom cement containing gentamicin had been used in the primary procedure. During revision hip replacement, samples of joint fluid, tissues and cement were taken both before and after disruption of the cement. With the exception of one sample of joint fluid, low concentrations of gentamicin were recorded in the samples taken before the cement was disrupted, but after disruption the specimens contained gentamicin at concentrations high enough to inhibit or prevent growth of sensitive organisms. The cement contained very high levels up to ten years after insertion. Our findings suggest that no reliance can be placed on the microbiological assessment of specimens taken once cement splitting has started and that specimens should therefore be taken as early as possible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Release of Gentamicin and Vancomycin from Preformed Spacers in Infected Total Hip Arthroplasties: Measurement of Concentrations and Inhibitory Activity in Patients' Drainage Fluids and Serum

Gentamicin (G) and vancomycin (V) concentrations in drainage fluids obtained from patients during the first 24 hours after implantation of antibiotic-loaded polymethylmethacrylate (PMMA) spacers in two-stage revision of infected total hip arthroplasty were studied. The inhibitory activity of drainage fluids against different multiresistant clinical isolates was investigated as well. Seven hips ...

متن کامل

Cement-in-cement acetabular revision with a constrained tripolar component.

Dislocation of a total hip replacement (THR) is common following total hip arthroplasty (THA). When nonoperative management fails to maintain reduction, revision surgery is considered. The use of constrained acetabular liners has been extensively described. Complete removal of the old cement mantle during revision THA can be challenging and is associated with significant complications. Cement-i...

متن کامل

The association between cement type and the subsequent risk of revision surgery in primary total hip replacement

Background and purpose - To further improve the success of joint replacement surgery, attention needs to be paid to variations associated with improved or worsened outcomes. We investigated the association between the type of bone cement used and the risk of revision surgery after primary total hip replacement. Methods - We conducted a prospective study of data from the National Joint Registry ...

متن کامل

New uses for gentamicin-impregnated polymethyl methacrylate spacers in two-stage revision hip arthroplasty.

The use of antibiotic-impregnated cement as a bone spacer in two-stage revision hip surgery has been well described. Two additional placements for spacers are described: within the trochanteric osteotomy and overlying the greater trochanter. These spacers have been found to dramatically facilitate exposure at the second-stage procedure and are now being incorporated into all two-stage revision ...

متن کامل

Bone cement product and failure in total knee arthroplasty

Background and purpose - The bone cement market for total knee arthroplasty (TKA) in Norway has been dominated by a few products and distributors. Palacos with gentamicin had a market share exceeding 90% before 2005, but it was then withdrawn from the market and replaced by new slightly altered products. We have compared the survival of TKAs fixated with Palacos with gentamicin with the surviva...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 80 4  شماره 

صفحات  -

تاریخ انتشار 1998